Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 45 (1996), S. 907-922 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Kiefergelenke ; endotracheale Intubation ; elektronische Achsiographie ; Key words Endotracheal intubation ; Temporomandibular joint ; Dysfunction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Laryngoscopy causes temporary postoperative dysfunction of the temporomandibular joint (TMJ): during iatrogenic TMJ manipulation in anaesthetised patients, the TMJs have lost the protection afforded by the tone of the surrounding muscles. Thus far, the exact type and extent of TMJ movements have not been known. The purpose of this study was to develop a method to visualise and assess TMJ movements during intubation by means of electronic axiography, a diagnostic monitor of TMJ movements used in dentistry: registration of the hinge axis (HA) as an equivalent of the condylar paths on extra-oral sagittally mounted, parallel plates. The HA is individually defined in each patient by the pure, rotating TMJ movement during initial mouth opening (no farward gliding of the condyles, incisor distance up to 10 mm). The parallel plates are placed in the TMJ region in the skull-mounted plate bow; both registration tips („drawing“ the HA tracings on the electronic plates) are connected to the mandible by a face bow, paraocclusally fixed to the teeth. The face bow is individually shaped for each patient to allow mask ventilation and free movement of the laryngoscope during intubation. HA tracings are registered and calculated for both sides independently every 24 ms with the SAM/Klett system and presented on sagittal and frontal projections. In the operating theatre, the active mouth-opening traces (MOT) are registered first and the passive endotracheal intubation traces (EIT) after induction of anaesthesia (same head position). With informed consent and approval by the ethics committee of the Landesärztekammer Rheinland-Pfalz, 40 male patients (ASA I, Mallampati I, limb surgery) were randomly allocated to four groups (n=10 each). OS: Oral intubation, suxamethonium (1.5 mg/kg); OV: Oral intubation, vecuronium (0.1 mg/kg); NS: Nasal intubation, suxamethonium (1.5 mg/kg); and NV: Nasal intubation, vecuronium (0.1 mg/kg). Intubation was performed 100 s after injection of the relaxant. Pre- and postoperatively (every 24 h over 3 days, in case of positive findings longer) recorded were: active movements of the mandible (maximal mouth opening/max. laterotrusion); dysfunction of the TMJ; and pain sensation in the TMJ (Helkimo rating). MOTs and EITs were recorded and analysed with the system described and typical EIT patterns were identified: bland, clinically uneventful intubations (n=7), massive distraction and laterotrusion of the EIT compared to the MOT (n=24), and blocked or limited TMJ movements resulting in intubation problems (n=1). With the method presented, TMJ movements could be visualised during endotracheal intubation for the first time. It can be used to assess techniques, routes, and instruments for intubation as well as to evaluate potential traumatising movements during endotracheal intubation.
    Notes: Zusammenfassung Zwischen der Funktion der Kiefergelenke und der Intubation besteht eine wechselseitige Beziehung: Dysfunktionen können ein Intubationshindernis darstellen. Die Intubation kann umgekehrt auch zu Funktionsstörungen im orofazialen System führen oder Auslöser akuter Kiefergelenkbeschwerden sein. Eine Aussage zu der nach Aufhebung der physiologischen Schutzmechanismen möglicherweise veränderten Motilität war bislang nicht möglich. Die Arbeit beschreibt die Anwendung einer Methode zur Erfassung der Kiefergelenkbewegungen sowie typische Befunde während der Intubation. Das Prinzip der elektronischen Achsiographie wurde dahingehend modifiziert, daß der Vergleich einer aktiven Mundöffnungsbewegung mit der Intubationsbewegung möglich wurde. Anhand der Ergebnisse von 40 Patienten (orale oder nasale Intubation, Relaxation mit Suxamethonium oder Vecuronium) konnten typische Kiefergelenkbewegungen demonstriert werden: Die Narkoseeinleitung führte zu einer Passivverlagerung nach kaudal, während der Einführung des Layngoskops verblieben die Gelenke in einer reinen Rotationsbewegung (physiologisch: Translationsbewegung). Die Einstellung der Trachea führte zu einer massiven (pathologischen) Distraktion. In einem Fall wurde die Ruptur des Ligamentum laterale dokumentiert. Die Methode erlaubt erstmals die Visualisierung der Kiefergelenkbewegungen während der Intubation. Als potentiell schädigende Momente wurden die unphysiologisch weite initiale Rotation und eine massive Kiefergelenkdistraktion identifiziert. Das Verfahren eröffnet die Möglichkeit, verschiedene Techniken, Medikamente und Instrumente zu untersuchen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 45 (1996), S. 923-930 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Airway-Management ; Schwierige Intubation ; Trachlight ; Transilluminationstechnik ; Key words Airway management ; Difficult intubation ; Light-guided intubation ; Trachlight®
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract The technique of light-guided intubation is based on the principle that a source of light brought into the trachea results in clearly visible and defined transcutaneous illumination, while no illumination can be observed with the light source in the oesophagus (Fig. 1–7). The Trachlight® is a reintroduced instrument for this alternative intubation technique. The essential developments are: a length-adjustable stylet with a removable internal metal wire, a brighter light source, a stable handle with tight fixation of the endotracheal tube, and a time-dependent warning device to avoid extended intubations. One hundred twenty patients (Mallampati I, ASA I–III) were included in the study (conventional intubation [group KL, n=60], Trachlight® intubation [group TT, n=60]. The goals of the investigation were to examine the handling, application, problems, limitations, and possible indications of the method. The recorded parameters were: number of intubation attempts: course and duration of intubation; complications; and difficulties. In 40 patients (20 in each group) the indication for invasive blood presure measurement was given due to the surgical procedure, and circulatory parameters were recorded at defined moments during the intubation course. In group KL 55 patients were intubated in the attempt, 4 on the second, and 1 on the third (mean duration 23.6±10.4 s, range 12–60 s). Complications were: unilateral intubation (3 patients), bradycardia (2), asystole (1) and soft-tissue injury (1). Of the 60 patients in group TT, 54 were intubated successfully, the mean time needed being 29.9±14.8 s (range: 6–61 s). The remaining 6 were then intubated by the conventional method. Positive results in group TT included: easy handling and application, no injury to soft tissues or teeth, and invariably correct placement of the tube. Problems included: sufficient transillumination was achieved only after (entire) dimming of the room, insufficient control over the distal end of the tube due to an unfixed metal wire, unintentional switching off of the light while with-drawing the metal wire, difficulties in with-drawing the metal wire (too strong fixation), as well as disturbing effects of the warning device (blinking of the light 30 s after switching on). Reasons for the 6 intubation failures were introduction of the instrument into the oesophagus despite a supposed correct position, impossibility of correct placement in a patient with an extremely large goiter, and insufficiently clear transillumination in 3 extremely obese patients. The cardiovascular parameters showed no changes during laryngeal manipulation; a clear rise in heart rate and blood pressure was recorded, however, when the tube was inserted into the trachea. The cardiovascular parameters during conventional intubations were similar. The light-guided intubation technique can be regarded as a further alternative for airway management, due to the described improvements of the instrument. The indication for the technique is given in patients in whom no difficulty with intubation is expected, to avoid soft tissue damage and traumatising temporomandibular joint movements. Preclinical use may be limited due to environmental brightness. In patients with expected difficult airway management, fiberoptic intubation will remain the method of choice.
    Notes: Zusammenfassung Bei der Transilluminationstechnik führt eine Lichtquelle zur transkutanen Durchleuchtung im Larynxbereich. Das Trachlight ® ist ein hierfür neues Instrument mit wesentlichen Weiterentwicklungen: längenadaptierbares Führungsstilett mit innerem Metalldraht, hellere Lichtquelle, stabiler Handgriff mit Fixation des Tubus und Zeitautomatik zur Warnung vor zu langer Intubationsdauer. Das neue Instrument wurde randomisiert im Vergleich zur konventionellen Intubation eingesetzt (n=120). Meßparameter: Anzahl, Verlauf der Intubationsversuche und Komplikationen. Bei jeweils 20 Patienten wurden die Kreislaufparameter invasiv erfaßt. Mit dem Trachlight ® konnten 54 Patienten erfolgreich intubiert werden (Zeitbedarf 29,9±14,8 s [6–61 s]), konventionell 23,6±10,4 (12–60 s). Positiva: Einfache Handhabung, keine Verletzungen, korrekte Einführtiefe des Tubus. Probleme: Ausreichende Transillumination erst nach völliger Abdunkelung, unzureichende Kontrolle über distales Tubusende, unbeabsichtigtes Ausschalten der Lichtquelle, Schwierigkeiten beim Zurückziehen des Metalldrahts sowie Störung durch den Blinkmechanismus. Gründe für Intubationsversager: Einführung des Instruments in den Ösophagus trotz vermeintlich korrekter Position, Unmöglichkeit der Plazierung sowie unzureichende Transillumination. Die Kreislaufparameter zeigten in beiden Gruppen keine Veränderungen während der laryngealen Manipulation, jedoch einen deutlichen Anstieg beim Vorschieben des Tubus in die Trachea. Die Transilluminationstechnik kann als eine Alternative im Airway-Management bezeichnet werden. Im präklinischen Bereich ist sie problematisch, bei Patienten mit schwierigen Intubationsverhältnissen sollte der Fiberoptik der Vorzug gegeben werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1436-0578
    Keywords: Schlüsselwörter Combitube™ ; Atemwegsmanagement ; Alternative Intubationsverfahren ; Schwierige Intubation ; Keywords Combitube™ ; Airwaymanagement ; Alternative airway devices ; Difficult intubation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Issues concerning the Combitube™, as indications of use, optimal insertion technique, and correct position are not yet answered. However, studies and case reports proved the successful use of the Combitube™. Goal of the present study was to analyse the Combitube™ position after insertion with different techniques via fibreoptic examination. 20 patients were intubated via Combitube™ with (n=10) or without (n=10) laryngoscope. In 10 patients a bending manoeuvre of the Combitube™ was performed before insertion (n=5 with and n=5 without laryngoscope). After insertion, the Combitube™ position was analysed via fibreoptic examination. In 19 out of 20 patients insertion of the Combitube™ was successful. No difference concerning insertion times, tube position and mucosal damage between laryngoscopic and non-laryngoscopic insertion and with or without bending manoeuvre was found. Fibreoptic examination proved ventilating perforations covered with mucosa in all patients with a mean of 3.7 out of 8 perforations free. In 9 cases blood clots were seen on the Combitube™, 15 out of 19 tubes were not placed as suggested by the manufacturer. For trained medical personnel, the Combitube™ is a suitable intubation device in emergency medicine and for the management of the difficult airway. Modifications of the ventilating perforations and the bands on the tube showing the right insertion depth may be considered. A frequent lesion of soft tissues caused by the Combitube™ is ascertained.
    Notes: Zusammenfassung Für den Combitube™ sind Fragen zu Anwendungsgebieten, optimaler Insertionstechnik und korrekter Positionierung bis heute nicht abschließend untersucht, die erfolgreiche Anwendung wurde jedoch in mehreren Studien und Fallberichten nachgewiesen. Ziel dieser Untersuchung war es, die Lage des Combitube™ nach Einführung mittels unterschiedlicher Insertionstechniken durch fiberoptische Untersuchung zu analysieren. Bei 20 Patienten wurde abwechselnd laryngoskopisch (n=10) und nicht-laryngoskopisch (n=10) ein Combitube™ eingeführt. Bei 10 Patienten erfolgte zusätzlich eine Vorbiegung des Combitube™ (n=5 mit und n=5 ohne Laryngoskop). Nach Positionierung des Tubus erfolgte die Lagekontrolle mittels fiberoptischer Untersuchung. Bei 19 von 20 Patienten wurde der Combitube™ erfolgreich eingeführt, Unterschiede bezüglich Insertionszeiten, Tubuslage und Schleimhautschäden zwischen laryngoskopischer und nicht-laryngoskopischer Einführung sowie mit oder ohne Vorbiegung konnten nicht festgestellt werden. Das Einführen nach Vorbiegen wurde jedoch als einfacher empfunden. Die fiberoptische Kontrolle ergab bei allen Patienten durch Schleimhaut verlegte Ventilationsperforationen, wobei im Mittel 3,7 von 8 Perforationen frei waren. Allein 9 Tuben wiesen Blutspuren auf und 15 Tuben waren nicht wie vom Hersteller angegeben positioniert. Der Combitube™ ist zur Atemwegssicherung in Notsituationen durch Eingewiesene geeignet. Modifikationen der Ventilationsperforationen sowie der Markierungen zur richtigen Insertionstiefe sind überlegenswert. Eine Schleimhautschädigung ist gehäuft festzustellen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗