Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 153-159 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Glass capillaries ; OH-terminated polysiloxanes ; Thermal immobilization ; Surface bonding ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Differently pretreated glass capillaries were coated with hydroxy-terminated methyl or methyl-phenyl polysiloxane gum phases and cured at 340-360°C for several hours. The volatile reaction products formed during the baking procedure were analyzed and the retention behavior of various polar test compounds were investigated both before and after the heat treatment. The findings were used to establish a reaction scheme which explains crosslinking and surface bonding of hydroxy-terminated silicone phases in high-temperature-silylated glass capillaries. The principle has been extended to the immobilization of common endcapped silicone phases by mixing them with hydroxy-terminated phases.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 209-214 
    ISSN: 0935-6304
    Keywords: Dual capillary gas chromatography ; non-methane hydrocarbons (NMHCs) ; refocusing ; PLOT column ; carbon dioxide interference ; ambient air analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An analytical method based on a dual capillary gas chromatographic technique combining the advantages of GasPro PLOT and a non polar narrow bore WCOT column was developed for the analysis of air samples containing C2-C9 NMHCs. A refocusing step was not required due to the fast heating rate of the sample preconcentration trap and the resolving power of the PLOT column for C2 and C3 NMHCs. Water had to be removed from the air samples to avoid plugging of the columns if the initial GC oven temperature was below ambient temperature. To dry air samples, a scrubber and a cryogenic technique were employed. The interferences caused by carbon dioxide were reduced by purging the loaded sample preconcentration trap with helium. The dual column system was compared to a method employing a refocusing device and a single narrow bore WCOT column. Both systems provided a high degree of precision. However, the dual column approach was superior to the single column system due to better resolution of low molecular weight components.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...