Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 45 (1982), S. 249-259 
    ISSN: 1432-0584
    Keywords: Complement, C3b ; Hemoglobinuria, paroxysmal ; Anemia, hemolytic
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The efficiency of cytolysis by the terminal complement proteins C5b-9 can be markedly enhanced by C3b molecules bound on the target cell membrane (Hammer et al. 1976). This enhancement was shown to be proportional to the number of C3b molecules on the cell membrane. The present experiments have shown that the hemolytic efficiency of the complement membrane attack system is two to five times greater on paroxysmal nocturnal hemoglobulinuria erythrocytes (PNHE) than on normal human E. This difference is attribut to a derivative of C3, probably C3b, on PNHE since it was abolished by anti-C3 but not by anti-C2. The efficiency of C5b-9 to lyse PNHE was only partially decreased by C3b inactivator and β 1H, indicating that the C3b on PNHE is not readily inactivated by its regulatory proteins. Furthermore, cells from a single severely affected patient consumed 3-fold more C5b6 than normal human E yet concommitantly measured membrane fluidity was normal. From these observations we conclude that cell-bound C3b on PNHE serves two functions: (a) it increases the hemolytic efficiency of membrane attack components of the complement system; and (b) it provides sites for assembly of the alternative pathway convertases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 5 (1984), S. 279-299 
    ISSN: 1572-9559
    Keywords: near millimeter waves ; optically pumped molecular laser ; Rexolite ; TPX ; Dynasil 4000
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A simple and versatile instrument for the measurement of optical constants in the near millimeter spectral region is described. Studies of quasi-optical components used in this instrument for effective beam transmission and control are reported. These studies include transmission characteristics of dielectric waveguides and performance of a variable coupler based on frustrated total internal reflection. Operation of this instrument as a two-beam interferometer for determining the index of refraction or as a device to measure transmission for determining the absorption coefficient are described. Values measured with this instrument at 245 GHz, using an optically pumped molecular laser as the source, are reported for several low-loss materials. Appropriate corrections and error estimates are discussed. The potential for improvement and increased accuracies are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...