ISSN:
1615-6102
Keywords:
Continuous flow cultivation system
;
Growth characteristics
;
Tetrahymena pyriformis
Source:
Springer Online Journal Archives 1860-2000
Topics:
Biology
Notes:
Summary A completely liquid-filled culture chamber with gas exchange across a synthetic membrane (Larsen andNilsson 1985) was incorporated into an automatic continuous flow system. The absence of an airliquid interface in the system permits removal of cell samples, and addition of fresh medium, under strictly sterile conditions. In this system,Tetrahymena pyriformis can be kept under optimal growth conditions in a rich nutrient medium and any defined cell density may be maintained for extended periods of time by varying the dilution rate of the culture. Furthermore, it has been possible to demonstrate, in the slope of the growth curve, even small changes which are difficult to detect in batch cultures since the duration of these changes is short. In the continuous flow system, the relative cell volume distribution and the food vacuole forming capacity of the cells were unaltered; however, all cells contained small refractive granules. The system permits the culture volume to be varied, but a standard volume of 20 ml was maintained in most experiments. Since the culture volume is small, the system requires less than one liter of fresh medium per week to maintain the cells in the exponentially multiplying growth phase.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF01275796
Permalink