Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (6)
  • Heme electronic structure  (3)
  • Impedance plethysmography  (3)
Source
  • Articles: DFG German National Licenses  (6)
Material
Years
  • 1
    ISSN: 0014-5793
    Keywords: Heme electronic structure ; Heme methyl resonance ; Myoglobin ; NMR ; Proximal histidyl imidazole orientation
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochimica et Biophysica Acta (BBA)/Protein Structure and Molecular 1163 (1993), S. 287-296 
    ISSN: 0167-4838
    Keywords: Heme ; Heme electronic structure ; Hypeffine shift ; Myoglobin ; NMR ; Nuclear Overhauser effect
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1327
    Keywords: Key words Fluorine-19 nuclear magnetic resonance ; Heme electronic structure ; Myoglobin ; Paramagnetic shift ; Reconstituted protein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract  A novel C 2-symmetric ring-fluorinated hemin, 13,17-bis(2-carboxyethyl)-2,8,12,18-tetramethyl-3,7-difluoroporphyrinatoiron(III), has been synthesized and was incorporated into sperm whale apomyoglobin to investigate protein-induced rhombic perturbations on the electronic structure of the active site of myoglobin (Mb) using 19F NMR spectroscopy. NMR signals for 19F atoms introduced as substituents on the present heme in ferrous low-spin and high-spin and ferric low-spin complexes have been observed and their shifts sharply reflect not only the electronic nature of the heme iron, but also in-plane asymmetry of the heme electronic structure. The two-fold symmetric electronic structure of the ring-fluorinated hemin is clearly manifested in the 19F and 1H NMR spectra of its dicyano complex. The chemical equivalence of the two fluorine atoms of the heme is removed in the active site of myoglobin and the splitting of the two 19F NMR signals provides a quantitative probe for characterizing the rhombic perturbation of the heme electronic structure induced by the heme-protein interaction. The in-plane asymmetry of heme electronic structures in carbonmonoxy and deoxy Mbs have been analyzed for the first time on the basis of the shift difference between the two 19F NMR signals of the heme and is interpreted in terms of iron-ligand binding and/or the orbital ground state of the heme. A potential utility of 19F NMR, combined with the use of a symmetric fluorinated hemin, in characterizing the heme electronic structure of myoglobin in a variety of iron oxidation, spin, and ligation states, is presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 28 (1990), S. 113-118 
    ISSN: 1741-0444
    Keywords: Digital blood flow ; Impedance plethysmography ; Laser Doppler ; Occlusion plethysmography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Digital volume changes and blood flow have been measured with impedance and strain-gauge plethysmography as well as with laser Doppler flowmetry. A good agreement was found between the impedance and strain-gauge flow measurements with a correlation coefficient of 0·905. The laser Doppler method recorded minor changes in finger skin blood flow following changes in posture from 30 cm below heart level to 60 cm above heart level. This result can be explained as a consequence of the limited penetration depth of laser light into the skin or as a sign of autoregulation of skin blood flow. In these experiments the total blood flow to the finger underwent major changes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 29 (1991), S. 419-424 
    ISSN: 1741-0444
    Keywords: Blood flow in human limbs ; Disk electrode ; Electrode system ; Impedance plethysmography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Electrode design and electrode positioning are important factors in blood flow measurements using impedance plethysmography. Optimal electrode type and accurate positioning will decrease measurement errors and improve the signal-to-noise-ratio. Disk electrodes were found to be superior to tape electrodes because of their better skin-electrode stability and because they prevent limb compression. The distance between current electrodes and potential electrodes should be greater than 2·3 R (disk electrodes) and 1·5 R (tape electrodes) to avoid the influence of the so-called diffusion resistance (R is the radius of the limb at the electrode site).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 30 (1992), S. 518-524 
    ISSN: 1741-0444
    Keywords: Blood flow in human limb ; Cross-sectional area ; Impedance plethysmography ; Strain gauge
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The cross-sectional area of a limb varies along the extremity. This is of great importance when impedance plethysmography is used for limb blood flow studies. The actual measurement site, as well as the interelectrode distance, must be carefully selected to avoid underestimation of the blood flow value. The distance between the potential electrodes should be less than 10 cm for an adult subject.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...