Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 123-125 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Column technology ; LC-like packed capillary columns ; Hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary columns of 0.3-0.35 mm internal diameter and 0.3-7.7 m length, packed with 3 to 30 μm octadecylsilica stationary phases as used for liquid chromatography, were applied to gas chromatographic separation of low boiling hydrocarbons. Van Deemter plots for these columns showed the optimum column efficiency to occur at linear velocities of 4-5 cm/s. A short column was applied to the rapid separation of components of a natural gas and impurities in standard gases, while a long column was applied to the separation of complex mixtures.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 13 (1990), S. 606-609 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; LC-type microcolumns ; Hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary columns of 0.3-0.5 mm i.d. packed with 3- to 30-μm silica-based stationary phases for liquid chromatography were used for gas chromatographic separation of hydrocarbons. Column efficiencies were evaluated for various commercially available packing material. The best column efficiency was achieved with 5-μm octadecyl group bonded silica gel, the surface of which was coated with a poly (dimethylsiloxane) film. The 30-cm column produced 11,000 theoretical plates.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...