Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2307
    Keywords: C-kit product ; Immunohistochemistry ; Human normal tissue ; Small cell lung carcinoma ; Seminoma/dysgerminoma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Eighteen hundred and eighty-four cases of human solid tumours and 833 samples of normal human tissues, formalin-fixed and paraffin-embedded, were examined immunohistochemically for expression of c-kit oncogene product using polyclonal antibody against synthesized c-kit peptide. Seminoma/dysgerminoma and small cell lung carcinoma (SCLC) show preferential c-kit expression at 92% and 36% frequency, respectively, whereas only sporadic cases of cervical carcinoma and non-SCLC lung carcinoma show c-kit positivity. A normal tissue counterpart positive for c-kit product is detected in the testis (spermatocyte) and ovary (oocyte) but not in the lung or the cervix. In contrast, normal epithelial cells of the breast, skin basal cells and tissue mast cells harbour c-kit product, but transformed cells of the former two are largely deficient in the c-kit protein. One hundred and thirty-nine neuroendocrine tumours and 39 non-pulmonary small cell carcinomas were all negative, except for two cases of neuroblastoma. This indicates a distinct character for SCLC in c-kit expression. The c-kit product may be a useful marker in diagnostic pathology of seminoma/dysgermona and SCLC among human solid tumours, and in distinction of SCLC from non-pulmonary small cell carcinoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 25 (1981), S. 311-316 
    ISSN: 1432-0630
    Keywords: 07.40 ; 07.60 ; 42.60 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract A high precision wavelength meter in the visible is described, which is based on a Fabry-Perot interferometer with several etalons of different resolution. The interference fringe pattern projected on a photo-diode array detector is computationally processed to give a stepwise refinement of the wavelength value to any adjusted accuracy. The present model intends to provide digital and real-time values of high precision wavelength for dye-laser spectroscopy, and to serve as a monitor or as a pilot for wavelength control of a dye-laser source of nanosecond pulses. The model is, therefore, designed with particular emphasis on its short-pulse capability and on-line mode of operation as well as on its high sensitivity and resolution. Some arrangements of essential necessity are involved therein, such as to avoid an errorneous wavelength readout for a noisy incidence of pulsed field. The ultimate accuracy of wavelength measurement is prescribed by the resolving power of the thickest etalon employed. As applied to the pulsed source, the model determines the wavelength to the accuracy of ±one part in 107 for even a single shot nanosecond incidence of a fraction of μJ energy. The design and performance are described in connection to pulsed dye-laser incidence.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 17 (1978), S. 131-136 
    ISSN: 1432-0630
    Keywords: 42.10 ; 42.60 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Basic properties are given of the prism anamorphic expander of a Gaussian beam composed of a couple of prisms in tandem. Its shorter overall length for a given expansion, relative ease of optical adjustment, a sharp selection of polarization component, and rather small inclusive dispersion make it an excellent beam expander in a specific laser cavity. The design principle is presented of the prism system with a grating for an anastigmatic optical resonator for a dye laser of narrow linewidth and of short pulse duration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 24 (1981), S. 331-340 
    ISSN: 1432-0630
    Keywords: 06.60 ; 42.60 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract A full-automatic wavelength controled pulsed dye laser has been developed. With the control system, dye laser oscillations of nanosecond pulses are tuned to any wavelength in the visible or scanned in any sweep mode keeping the nearly transform-limited bandwidth of 0.45 GHz. A mechanical tuning of the wavelength is employed, such that the motion of three wavelength selectors is synchronized to give a smooth and precise wavelength control. The basic principle underlying the tuning scheme, various requirements to be met in system construction, and the practical performance of automatic wavelength control are described in this paper.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0711
    Keywords: Key words: 1-1-2 D ; Monoclonal antibody ; Immunohistochemistry ; Ovarian cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. 1-1-2 D, a novel human monoclonal antibody (MAb) raised against cervical cancer, was examined for its immunohistochemical reactivity with ovarian cancer. Six of 10 ovarian cancer cell lines showed positive staining, while 3 of 5 cervical cancer cell lines were positive. Among tumor tissues, 15 of 18 (83%) ovarian serous cystadenocarcinomas and 10 of 12 (83%) ovarian clear cell adenocarcinomas were positive. We also performed immunohistochemical staining of the same cancer specimens with OC 125 and compared their reactivity. The frequency of positivity was similar, but the reactivity of the two MAbs was different. 1-1-2 D stained the apical surface of the glandular epithelial cells and secretory products of the gland. On the other hand, OC 125 stained the cytoplasm as well as the plasma membrane of the glandular epithelial cells. These results suggest that 1-1-2 D MAb recognizes a different antigen from that recognized by OC 125.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-0711
    Keywords: 1-1-2D ; Monoclonal antibody ; Immunohistochemistry ; Ovarian cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract 1-1-2D, a novel human monoclonal antibody (MAb) raised against cervical cancer, was examined for its immunohistochemical reactivity with ovarian cancer. Six of 10 ovarian cancer cell lines showed positive staining, while 3 of 5 cervical cancer cell lines were positive. Among tumor tissues, 15 of 18 (83%) ovarian serous cystadenocarcinomas and 10 of 12 (83%) ovarian clear cell adenocarcinomas were positive. We also performed immunohistochemical staining of the same cancer specimens with OC 125 and compared their reactivity. The frequency of positivity was similar, but the reactivity of the two MAbs was different. 1-1-2D stained the apical surface of the glandular epithelial cells and secretory products of the gland. On the other hand, OC 125 stained the cytoplasm as well as the plasma membrane of the glandular epithelial cells. These results suggest that 1-1-2D MAb recognizes a different antigen from that recognized by OC 125.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...