    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 28 (1990), S. 212-216 
    ISSN: 1741-0444
    Keywords: Cardiac output ; Electrical field mapping ; Impedance cardiography ; Impedance plethysmography ; Stroke volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The cardiogenic impedance signal from band electrodes placed in the traditional position around the neck and lower thorax was studied by mapping the location of the signal on the sternum using 10 cm strip electrodes in eight male subjects. The band current electrodes on the neck and waist were replaced with 10cm strip electrodes on the forehead and 10 cm below the xiphisternal joint, respectively, with only small changes in the dZ/dt peak amplitude and Zo. Similarly, using a strip voltage pickup electrode at the level of the xiphisternal joint resulted in very small changes in the waveform. The amplitude of dZ/dt measured between the xiphisternal joint and points along the sternum remains small until approximately 10cm below the suprasternal notch, after which it increased linearly to the top of the neck. An average of 17 per cent and 24 per cent of the dZ/dt signal and 24 per cent and 22 per cent of the Zo signal for supine and standing, respectively, occurs above the suprasternal notch. Replacing the current electrodes with strip electrodes on the forehead and waist caused only small changes in the signal. The position of the neck strip electrode is more critical.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 30 (1992), S. 556-561 
    ISSN: 1741-0444
    Keywords: Filtering ; Impedance cardiography ; Respiration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 29 (1991), S. 505-510 
    ISSN: 1741-0444
    Keywords: Cardiac functions ; Impedance cardiography ; Respiratory effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The respiratory effects on impedance-determined cardiac indices ((dZ/dt)min, stroke volume (SV), the Heather index (HI) and the O-wave) were measured at 100 kHz on ten normal males in the supine and sitting positions. The respiration was synchronised to 1/5th of the heart rate using voluntary cardiorespiratory synchronisation (VCRS). Digital filtering was used to eliminate breathing artefacts in the impedance signals, SV, (dZ/dt)min and HI were statistically higher during inspiration than expiration. Ensemble-averaging of (dZ/dt) signals using the R spike of the ECG as reference will lose beat-to-beat information and statistically reduce (dZ/dt)min because of the variation of RZ intervals during respiration Zo increased with inspiration and decreased in expiration delayed by one heart beat. The ratio of the O-wave height to (dZ/dt)min changed by 48 per cent from the beginning of inspiration to the end of expiration. Based on the timing and direction of the changes, the data imply that the traditional band impedance measurement is more closely related to the right heart event than to that of the left heart.