Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    European spine journal 9 (2000), S. 571-576 
    ISSN: 1432-0932
    Schlagwort(e): Key words Spinal fusion ; Implants ; Biomechanics ; Computer simulation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract A high rate of pseudarthrosis and a high overall rate of implant migration requiring surgical revision has been reported following posterior lumbar interbody fusion using BAK threaded cages. The high rate of both pseudarthrosis and implant migration may be due to poor fixation of the implant. The purpose of this study was to analyse the motion of threaded cages in posterior lumbar interbody fusion. Six cadaveric human lumbar spine segments (three L2/3 and three L4/5 segments) were prepared for biomechanical testing. The segments were tested, without preload, under forces of axial compression (600 N), torsion (25 Nm) and shearing force (250 N). The tests were performed first with the segments in an intact state, and subsequently following instrumented stabilisation with two BAK cages via a posterior approach. These results were compared with those of a finite element model simulating the effects of identical forces on the segments with constructs. As the results were comparable, the finite element model was used for analysing the motion of BAK cages within the disc space. Motion of the implants was not seen in compression. In torsion, a rolling motion was noted, with a range of motion of 10.6° around the central axis of the implant when left/right torsion (25 Nm) was applied. The way the implants move within the segment may be due to their special shape: the thread of the implants can not prevent the BAK cages rolling within the disc space.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Child's nervous system 14 (1998), S. 263-270 
    ISSN: 1433-0350
    Schlagwort(e): Key words Ependyma ; Hydrocephalus ; Congenital disease model
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract H-Tx rats produce congenitally hydrocephalic offspring with varying severity of the condition. We used moderately hydrocephalic rats without evident clinical signs of hydrocephalus and normal controls from the same stock when they were at least 1.5 years old. Macroscopic anatomy was studied by MRI and in fixed brain slices and the ultrastructure of the ependyma, with REM. Apart from markedly stretched areas, where the ependyma was totally destroyed and subependymal structures directly exposed to the CSF, the density of ependymal microvilli and of tufts of cilia was reduced in proportion to the ventricular distension of a given area. A supraependymal “network”– never seen before in acute hydrocephalus – was found, whose purpose is probably to prevent further ventricular enlargement. We conclude that even in arrested hydrocephalus the ependymal sequelae of hydrocephalus are similar to those of the acute stage, illustrating the extremely limited potenctial for recovery, but the organism seems nevertheless to react with an internal stabilization of the ventricular system.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...