Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (1)
  • 1960-1964
  • Inferior vena caval blood flow  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 920-924 
    ISSN: 1432-2218
    Schlagwort(e): Cardiac hemodynamics ; CO2 pneumoperitoneum ; Inferior vena caval blood flow
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Background: The effects of carbon dioxide pneumoperitoneum on venous return and cardiac hemodynamics during laparoscopic surgery were studied. Methods: Twelve adult pigs underwent placement of an electromagnetic flow meter across the infrarenal vena cava (IVC) as well as placement of Swan Ganz and arterial monitoring catheters. Measurements of the flow through infrarenal IVC, cardiac output (CO), pulmonary capillary wedge pressure (PCWP), mean arterial pressure (MAP), and heart rate were recorded at baseline, 5 and 60 min following insufflation to 15 mmHg with CO2, and 5 min following desufflation. Stroke volumes and systemic vascular resistance (SVR) were calculated as well. Results: Flow through the IVC dropped by 24 and 31% at 5 and 60 min (p=0.03 and 0.02, respectively). Paradoxically, cardiac output rose by 14 and 28% at 5 and 60 min (p=0.03 at 60 min). Central venous and pulmonary capillary wedge pressures rose transiently by 35 and 36% at 5 min before returning to baseline (p〈0.01). Mean arterial pressure and heart rate remained relatively constant during insufflation. Systemic vascular resistance diminished from 938 dynes/cm/s prior to insufflation to its nadir at 60 min of 650 dynes/cm/s (p〈0.01). Conclusions: These observations suggest potentially complex interactions between the mechanical and systemic effects of the CO2 pneumoperitoneum on venous return. Transient elevations in cardiac filling pressures occur by an unknown mechanism, and a generalized enhanced inotropic state mediated via increased sympathetic outflow is observed in this hypercapnic anesthetized animal model.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...