Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Key words Dose-area product  (1)
  • Key words Helical CT  (1)
  • 1
    ISSN: 1433-0563
    Keywords: Schlüsselwörter Flächendosisprodukt ; Dosimetrie ; Durchleuchtung ; Radiographie ; Miktionszysturethrographie ; Key words Dose-area product ; Dosimetry ; Fluoroscopy ; Radiography ; Voiding cystourethrography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Objective: Determination of the proportion of the dose-area product caused by fluoroscopy at voiding cystourethrography in children, using digital image intensifier technology. Patients and methods: Using computer-assisted dosimetry, we determined the dose-area product and the respective proportions of the dose-area product caused by fluoroscopy and radiography as well as the number of radiographs taken at a given examination of 40 children (8 children less than 2 years old, 15 children between 2 and 6 years old and 17 children between 6 and 15 years old). Results: The computer software program correctly differentiated between fluoroscopy and radiography in 80 % of cases. Incorrect results were primarily observed in newborns and young children. The total radiation dose ranged in relation to patient age from 22 to 651 cGy × cm2. Fluoroscopy was responsible for an average 78 % of the applied radiation dose. Conclusion: Computer-assisted dosimetry is useful in determining the proportion of the dose-area product caused by fluoroscopy in older children undergoing voiding cystourethrography. When image intensifier technology is used, this accounts for more than 75 % of the total radiation dose. The method is not suitable for use in small children.
    Notes: Zusammenfassung Ziel: Bestimmung des Anteils der Durchleuchtung am Gesamtflächendosisprodukt beim Kindermiktionszysturethrogramm in digitaler Bildverstärkertechnik. Material und Methode: Bei 40 Kindern (8 Kinder 〈 2 Jahre, 15 Kinder zwischen 2 und 6 Jahren und 17 Kinder zwischen 6 und 15 Jahren) wurden PC-gestützt die Anzahl der Zielaufnahmen, deren Anteil am Gesamtflächendosisprodukt sowie der durchleuchtungsbedingte Anteil am Gesamtflächendosisprodukt ermittelt. Ergebnisse: In 80 % der Fälle ermöglichte der Einsatz des Computerprogramms eine korrekte Differenzierung zwischen Fluoroskopie und Radiographie. Falsche Ergebnisse fanden sich hauptsächlich bei Neugeborenen und Kleinkindern. Die Gesamtstrahlenbelastung variierte abhängig vom Patientenalter zwischen 22 und 651 cGy × cm2, durchschnittlich betrug der Anteil der Durchleuchtung 78 %. Schlußfolgerung: PC-gestützt ist es möglich den Anteil der Durchleuchtung am Gesamtflächendosisprodukt bei älteren Kindern, die sich einem Miktionszysturethrogramm unterziehen, zu ermitteln. Dieser beträgt bei Verwendung der digitalen Bildverstärkertechnik mehr als 75 %. Bei Neugeborenen und Kleinkindern versagt die Methode.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Spiral-CT ; Virtuelle Endoskopie ; Larynx ; Key words Helical CT ; Virtual endoscopy ; Larynx
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary This pilot study investigated the feasibility and clinical value of high-resolution virtual real-time laryngoscopy based on helical CT data sets. Nine patients with laryngeal pathology (three with tumors of the vocal cords, two laryngeal carcinomas, one with invasion of the larynx by thyroid carcinoma and six subglottic stenoses) underwent examination by helical CT at a collimation of 1 mm. Following acquisition, the images were processed at a workstation with standard visualization software, such that virtual endoscopy (VE) in real time was possible. The images were then compared with the findings of conventional endoscopy. Because of swallowing artifacts, reconstruction failed in 2 of 12 patients. None of the carcinomas of the vocal cords was recognized at VE or in the cross-sectional CT images. VE provided the correct diagnosis in 8 of 12 cases (laryngeal tumors, subglottic stenoses). Virtual laryngoscopy is capable of simulating the visual findings of endoscopy in cases of laryngeal tumors and subglottic stenoses. Small tumors of the vocal cords are not adequately visualized. The major problem affecting results is motion artifacts resulting from involuntary swallowing.
    Notes: Zusammenfassung Im vorliegenden Beitrag wird eine Pilotstudie zur Überprüfung der Machbarkeit und des klinischen Nutzens einer hochauflösenden virtuellen Echtzeitlaryngoskopie aus Spiral-CT-Datensätzen vorgestellt. 12 Patienten mit Erkrankungen im Kehlkopfbereich (3 Stimmlippentumore, 2 Larynxkarzinome, ein in den Larynx eingebrochenes Schilddrüsenkarzinom und 6 subglottische Stenosen) wurden mittels hochauflösender Spiral-CT (Kollimation 1 mm) untersucht. Anschließend wurden die Bilder auf einer Workstation mit einer standardmäßigen Visualisierungssoftware so rekonstruiert, daß eine virtuelle Endoskopie (VE) in Echtzeit möglich wurde, welche der herkömmlichen Fiberendoskopie gegenübergestellt wurde. 2 der 12 Patienten waren bedingt durch Schluckartefakte nicht zu rekonstruieren. Keines der Stimmlippenkarzinome war in der VE oder den Querschnittsbildern zu erkennen. In 8 von 12 Fällen war die VE diagnostisch (Larynxtumore, subglottische Stenosen). Die virtuelle Laryngoskopie in der hier beschriebenen Technik vermag Larynxtumoren und subglottische Stenosen, nicht aber kleine Stimmbandtumoren in einer dem Kliniker vertrauten endoskopischen Sichtweise darzustellen. Hauptproblem sind Bewegungsartefakte durch unwillkürliche Schluckbewegungen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...