Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1434-601X
    Keywords: PACS. 25.70.Lm Strongly damped collisions – 25.70.Pq Multifragment emission and correlations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: Primary and secondary masses of heavy reaction products have been deduced from kinematics and E-ToF measurements, respectively, for the direct and reverse collisions of 93Nb and 116Sn at 25 AMeV. Light charged particles have also been measured in coincidence with the heavy fragments. Direct experimental evidence of the correlation of energy-sharing with net mass transfer has been found using information from both the heavy fragments and the light charged particles. The ratio of hydrogen and helium multiplicities points to a further correlation of angular momentum sharing with net mass transfer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1246
    Keywords: Toluene ; Xylene ; Styrene ; Hippuric acid ; m-Methylhippuric acid ; Phenylglyoxylic acid ; Mandelic acid ; Urinary metabolites
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A new high-pressure liquid chromatography (HPLC) method for simultaneous quantitative determination of the urinary metabolites of toluene, m-xylene, and styrene (hippuric acid, m-methylhippuric acid, phenylglyoxylic acid, mandelic acid) is described. The extraction procedure was performed on acidified urines, after addition of 4-hydroxybenzoic acid as internal standard, using a butylchloride/isopropanol mixture and drying 0.5 ml of the organic layer under nitrogen flow. The residue obtained was dissolved in 0.1 ml water/acetonitrile and 5 μl were injected into an HPLC apparatus equipped with a 0.26 × 25 cm HC ODS SIL X column. Absorbance measures were performed at 225 nm throughout the investigation. All metabolites were clearly separated in a short time (12 min) and the amounts of other urinary compounds affecting the analysis were so small that the measurement of low concentrations of the urinary metabolites could be easily performed. Linear calibration curves were obtained from 0.1 to 3 mg/ml and a correlation coefficient greater than 0.99 was found between concentrations of the standards and areas of the peaks. Statistical analysis confirms that this method, which has a high reproducibility, is simple, reliable, and useful for the biologic monitoring of industrial exposure to aromatic compounds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...