    Schlagwort(e): Node of Ranvier ; Sodium Permeability ; Aconitine
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary The effect of aconitine (10−5–10−6 g/ml) on membrane potentials and membrane currents of myelinated nerve fibres of Xenopus laevis was investigated. The following observations were made: a) Current clamp conditions: Slow depolarization (10–15 mV), decrease of amplitude and maximum rate of rise of action potential, finally inexcitability. With inward current pulses ‘hyperpolarizing responses’ could be elicited at membrane potentials more negative than the resting potential (E r ). Neither spontaneous activity nor repetitive responses to electrical stimuli were observed. No effects of aconitine were found in Na-free solutions or in the presence of tetrodotoxin. b) Voltage clamp conditions: Development of steady inward current at normal resting potential due to formation of a non-inactivating sodium permeability; heavily poisoned nodes therefore exhibit an N-shaped steady-state current voltage relation with negative slope at membrane potentials more negative thanE r . These non-inactivating sodium channels open more slowly than normal sodium channels, and can only be closed by hyperpolarizing the membrane by about 50 mV. The majority of sodium channels have almost normalτ m; theirm ∞ andh ∞-V relations are shifted by 10–15 mV towardsE r . It is concluded that these changes of the sodium permeability account for the changes of electrical activity observed after treatment with aconitine.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Pflügers Archiv 333 (1972), S. 51-61 
    ISSN: 1432-2013
    Schlagwort(e): Node of Ranvier ; Ionic Currents ; Scorpion Venom ; Calcium Ions
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Voltage clamp experiments were done on myelinated nerve fibres of Xenopus laevis to study the effect of calcium on the ionic currents of the nodal membrane treated with scorpion venom. Increasing the calcium concentration of the medium from 1.8 to 7.2 mM produced the following changes of the sodium and potassium permeabilities,P Na andP K: a) The incomplete sodium inactivation, which is typical for nodes of Ranvier treated with scorpion venom, is abolished. The curves relatingm ∞ and τ m to membrane potential are shifted by 8–10 mV towards larger depolarizations.P Na and the time constants of the fast and slow components of the sodium inactivation remain practically unchanged. b) The maximum potassium permeability,P K, which is reduced by scorpion venom to 45% of the value observed in the normal node, increases to 68% by addition of calcium ions; τ n is unchanged. These effects of calcium ions on the ionic permeabilities explain the shortening of the extremely prolonged action potential and the inhibition of spontaneous activity observed in nodes of Ranvier poisoned with scorpion venom.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 0009-286X
    Schlagwort(e): Chemistry ; Industrial Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Für Batterien großer Energiedichte werden elektrochemische Systeme mit sehr elektronegativen Metallen in protonen-freien organischen Lösungsmitteln erwogen. Theoretische Überlegungen zeigen, daß aus physikalisch-chemischen und technischen Gründen neben einer Lithium-Anode für die Kathode nur eine sehr begrenzte Auswahl von Elektroden-Materialien in Frage kommt, was experimentell bestätigt werden konnte. Dreieckspannungsmessungen in Propylencarbonat ergaben, daß als Anode Lithium am besten geeignet ist, während für die Kathoden nur die Chloride des Silbers und Kupfers sowie für geringe Stromdichten noch die Fluoride dieser Metalle brauchbar sind. Die technischen Möglichkeiten derartiger Hochenergiebatterien sowie ihre Vor- und Nachteile gegenüber herkömmlichen Systemen werden diskutiert.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...