Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Membrane-extraction disks ; On-line trace enrichment ; Polar pollutants ; Surface water
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An on-line trace-enrichment system, using a bifunctional membrane extraction-disk cartridge, has been combined with a column liquid chromatography separation for the simultaneous determination of basic, neutral and acidic pollutants in surface water. The enrichment device consisted of a specially constructed holder containing both C-18 and cation-exchange disks. The holder can contain up to 25 disks of 0.5 mm thickness and 4.6 mm diameter. Before trace enrichment of 20 ml of surface water (pH 3.0), calcium ions were removed from the sample by means of an oxalic acid precipitation. Desorption of the cartridge was at elevated temperature using reversed-phase gradient elution; detection was performed with a diode-array UV absorbance detector. The detection limits for the test compounds in surface water are typically 0.5–2 μg/l; the calibration graphs are linear from the lower limit of determination up to 50 μg/l.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polar pollutants in water ; On-line trace enrichment ; Humic substances
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A practical liquid chromatographic early-warning system for polar pollutants in water ought to have detection limits at a level below a microgram per litre. Using ultraviolet absorbance detection this normally necessitates trace enrichment of the samples. In this study ten different sorbents have been tested with respect to their enrichment capacity. The hydrophobic polymeric PLRP-S material, in combination with a C-18 modified analytical column, proved to be the best choice. The influence of humic substances, present in surface water, was also studied. Lowering of the sample pH, resulted in a significant increase in the interferences due to the humic substances.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 313-345 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Sample pretreatment ; Coupling on-line to capillary GC ; Robotization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Sample pretreatment is often the bottleneck of a tracelevel analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of procedures in use today for sample treatment coupled on-line to capillary gas chromatography (GC) is briefly discussed. Special attention is devoted to coupled-column techniques such as SPE-GC and LC-GC (SPE, solid-phase extraction; LC, column liquid chromatography) which are topics of much current interest, also because of their frequent use in so-called hyphenated systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Narrow-bore column liquid chromatography ; Post-column derivatization ; Solid-phase reactors ; Catalytic hydrolysis ; On-line trace enrichment ; Immobilized enzyme
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of solid-phase reactors for post-column derivatization in narrow-bore HPLC (1.0mm i.d. analytical columns) is evaluated. Two systems are described, viz. for the determination of N-methylcarbamate pesticides and for that of urea and ammonia. The solid-phase reactor is packed with a strong anion exchange resin and urease immobilized on silica, respectively, to effect the catalytic hydrolysis of the solutes eluting from the analytical column. In both systems, the hydrolysis product is reacted with o-phthalaldehyde followed by fluorescence monitoring. Analytical data are presented and band broadening from various parts of the reaction detector system is discussed. An on-line trace enrichment procedure via a micro precolumn is descried for the trace level determination of N-methylcaramates in surface water samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Capillary electrophoresis ; On-line LC-CE ; Sample pretreatment ; Matrix effects ; Benzoic acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Various methods are currently under investigation to improve concentration detection limits in capillary electrophoresis (CE). Stacking and isotachophoresis coupled in-line with free-solution electrophoresis are the techniques most frequently used. Samples containing a high and/or varying salt concentration, such as urine and serum, are difficult to handle: usually a significant loss in electrophoretic efficiency is observed compared with samples possessing a low electric conductivity. In the present paper an alternative approach is developed, i.e. a liquid chromatographic (LC)-type of sample pretreatment is coupled on-line with CE. To demonstrate the feasibility of this approach, the separation of three model compounds (benzoates) in water containing up to 400 mM of sodium chloride is studied using a 50 mM borate CE buffer of pH 9.5. The direct injection of samples with high salt concentrations in CE results in peak splitting and/or serious band broadening. These problems are not encountered when using the present LC-CE system. In addition, the detection limits are hardly influenced by the salt concentration of the sample; this underlines the robustness of the system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...