Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1238
    Keywords: Key words Weaning ; CPAP ; BiPAP ; Extravascular lung water ; Cardiac surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To evaluate the effects of continuous positive airway pressure (CPAP) and bi-level positive airway pressure (BiPAP) on extravascular lung water during weaning from mechanical ventilation in patients following coronary artery bypass grafting. Design; Prospective, randomized clinical study. Setting; Intensive care unit at a university hospital. Patients; Seventy-five patients following coronary artery bypass grafting. Interventions; After extubation of the trachea, patients were treated for 30 min with CPAP via face mask (n=25), with nasal BiPAP (n=25), or with oxygen administration via nasal cannula combined with routine chest physiotherapy (RCP) for 10 min (n=25). Measurements and results: Extravascular lung water (EVLW), pulmonary blood volume index (PBVI) and cardiac index (CI) were obtained during mechanical ventilation (T1), T-piece breathing (T2), interventions (T3), spontaneous breathing 60 min (T4) and 90 min (T5) after extubation of the trachea using a combined dye-thermal dilution method. Changing from mechanical ventilation to T-piece breathing did not show any significant differences in EVLW between the three groups, but a significant increase in PBVI from 155±5 ml/m2 to 170±4 ml/m2 could be observed in all groups (p〈0.05). After extubation of the trachea and treatment with BiPAP, PBVI decreased significantly to 134±6 ml/m2 (p〈0.05). After treatment with CPAP or BiPAP, EVLW did not change significantly in these groups (5.5±0.3 ml/kg vs 5.0±0.4 ml/kg and 5.1±0.4 ml/kg vs 5.7±0.4 ml/kg). In the RCP-treated group, however, EVLW increased significantly from 5.8±0.3 ml/kg to 7.1±0.4 ml/kg (p〈0.05). Sixty and 90 min after extubation, EVLW stayed at a significantly higher level in the RCP-treated group (7.5±0.5 ml/kg and 7.4±0.5 ml/kg) than in the CPAP-(5.6±0.3 ml/kg and 5.9±0.4 ml/kg) or BiPAP-treated groups (5.2±0.4 ml/kg and 5.2±0.4 ml/kg). No significant differences in CI could be observed within the three groups during the time period from mechanical ventilation to 90 min after extubation of the trachea. Conclusions: Mask CPAP and nasal BiPAP after extubation of the trachea prevent the increase in extravascular lung water during x weaning from mechanical ventilation. This effect is seen for at least 1 h after the discontinuation of CPAP or BiPAP treatment.Further studies have to evaluate the clinical relevance of this phenomenon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Weaning CPAP ; BiPAP ; Extravascular lung water ; Cardiac surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To evaluate the effects of continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP) on extravascular lung water during weaning from mechanical ventilation in patients following coronary artery bypass grafting. Design Prospective, randomized clinical study. Setting Intensive care unit at a university hospital. Patients Seventy-five patients following coronary artery bypass grafting. Interventions After extubation of the trachea, patients were treated for 30 min with CPAP via face mask (n=25), with nasal BiPAP (n=25), or with oxygen administration via nasal cannula combined with routine chest physiotherapy (RCP) for 10 min (n=25). Measurements and results Extravascular lung water (EVLW), pulmonary blood volume index (PBVI) and cardiac index (CI) were obtained during mechanical ventilation (T1), T-piece breathing (T2), interventions (T3), spontaneous breathing 60 min (T4) and 90 min (T5) after extubation of the trachea using a combined dye-thermal dilution method. Changing from mechanical ventilation to T-piece breathing did not show any significant differences in EVLW between the three groups, but a significant increase in PBVI from 155±5 ml/m2 to 170±4 ml/m2 could be observed in all groups (p〈0.05). After extubation of the trachea and treatment with BiPAP, PBVI decreased significantly to 134±6 ml/m2 (p〈0.05). After treatment with CPAP or BiPAP, EVLW did not change significantly in these groups (5.5±0.3 ml/kg vs 5.0±0.4 ml/kg and 5.1±0.4 ml/kg vs 5.7±0.4 ml/kg). In the RCP-treated group, however, EVLW increased significantly from 5.8±0.3 ml/kg to 7.1±0.4 ml/kg (p〈0.05). Sixty and 90 min after extubation, EVLW stayed at a significantly higher level in the RCP-treated group (7.5±0.5 ml/kg and 7.4±0.5 ml/kg) than in the CPAP-(5.6±0.3 ml/kg and 5.9±0.4 ml/kg). No significant differences in CI could be observed within the three groups during the time period from mechanical ventilation to 90 min after extubation of the trachea. Conclusions Mask CPAP and nasal BiPAP after extubation of the trachea prevent the increase in extravascular lung water during weaning from mechanical ventilation. This effect is seen for at least 1 h after the discontinuation of CPAP or BiPAP treatment. Fuether studies have to evaluate the clinical relavance of this phenomenon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal für Praktische Chemie/Chemiker-Zeitung 339 (1997), S. 482-484 
    ISSN: 0941-1216
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: On the Mass Spectrometric Characterization of ω-Chloralkylphenylphosphines
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal für Praktische Chemie/Chemiker-Zeitung 338 (1996), S. 627-633 
    ISSN: 0941-1216
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: On Surface Compounds of Transition Metals. XL. Characterization of Chromium Doped Silica Catalyst Systems of the Phillips Type by Scanning Electron Microscopy with Energy Dispersive Analysing System (SEM/EDS)The surface of typical supports for the Phillips catalyst was studied by SEM. The seemingly smooth surfaces are composed by closely packed, ball-shaped substructures; macro- and micro-pores can be seen. Adherent particles on the surface (φ ≪ 1 μm) show the same substructures as the usual surface. After impregnation and activation/reduction of the catalysts crystallites are seen at the surface, which are characterized as Cr2O3 by their crystal shape and EDS analysis.Polymerization of ethylene occurs at the usually doped surface, while the Cr2O3 particles do not exhibit a special activity. Mechanically inforced breaks of the catalyst grains show the formation of threadlike polyethylene with diameters of 200 to 300 nm.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...