Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (2)
  • 67.40.-w  (1)
  • Abies grandis  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of chemical ecology 16 (1990), S. 2713-2722 
    ISSN: 1573-1561
    Keywords: Monoterpenes ; Abies grandis ; Picea pungens ; steam distillation ; extraction ; secondary chemicals ; grand fir ; blue spruce ; coefficient of variation ; MANOVA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract Five extraction techniques were used to obtain quantitative measurements of monoterpenes from blue spruce and grand fir needles. Multivariate analysis of variance indicated that there was a significant difference in the amount of each monoterpene extracted by using different techniques. For both species, an 8-hr steam distillation of 10 g of material yielded the greatest amount of each monoterpene. This technique was also the most reproducible in that the coefficients of variation were lowest. A rapid steam distillation was relatively effective for grand fir, but not for blue spruce. A CO2 extraction was unreliable for both species.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of low temperature physics 93 (1993), S. 907-919 
    ISSN: 1573-7357
    Keywords: 67.40.-w ; 67.40.Db ; 05.30.Jp
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We briefly review some general aspects of Bose condensation and off-diagonal long range order in infinite bulk systems and then discuss to what extent these features might be manifested in finite systems with free surfaces such as droplets of liquid 4 He at low temperatures. We focus on the structure of the one-body density matrix and the macroscopic wave function in the surface region, and note the possibility of a surface condensate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 8 (1998), S. 101-105 
    ISSN: 1057-9257
    Keywords: biosensor ; protein immobilisation ; protein modification ; electrochemistry ; nitrotyrosine ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Use of electrosynthetic methodology allows the production of hen egg-white lysozyme (HEWL) either mononitrated at tyrosine 23 or bisnitrated at tyrosines 20 and 23, but never nitrated at tyrosine 53. This is a different sequence from that obtained by the chemical nitrating agent tetranitromethane, and when reduced by dithionite, the selectively modified enzyme can be anchored at pH 5 via the unique aromatic amino group to magnetic beads or other suitable matrices. HEWL so immobilised loses less than 10% of cell-wall lytic activity compared with the approximately 50% loss of activity when immobilised by conventional methodology at pH 9 via essentially random reaction at lysine residues and other functionalities which are nucleophilic at this pH. This result offers promise as a general method for selective protein immobilisation in biosensors and similar applications. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 405-414 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Corrosion resistance is particularly important in medical treatments requiring implantation of metallic objects in the human body. Unfortunately, weight loss measurements and other conventional corrosion testing techniques are insufficiently sensitive and difficult to adapt to in vivo environments. The linear polarization technique can be used to remotely meaure the corrosion rates of metals implanted in tissue using needle probes. The principles of this technique are reviewed and the results of tests performed on steel, cobalt, and molybdenum implanted in experimental animals are discussed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...