Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Aequationes mathematicae 40 (1990), S. 248-260 
    ISSN: 1420-8903
    Keywords: Primary 05B05 ; Secondary 05C20
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Notes: Summary Letv andK be positive integers. A (v, k, 1)-Mendelsohn design (briefly (v, k, 1)-MD) is a pair (X,B) whereX is av-set (ofpoints) andB is a collection of cyclically orderedk-subsets ofX (calledblocks) such that every ordered pair of points ofX are consecutive in exactly one block ofB. A necessary condition for the existence of a (v, k, 1)-MD isv(v−1) ≡ 0 (modk). If the blocks of a (v, k, 1)-MD can be partitioned into parallel classes each containingv/k blocks wherev ≡ ) (modk) or (v − 1)/k blocks wherev ≡ 1 (modk), then the design is calledresolvable and denoted briefly by (v, k, 1)-RMD. It is known that a (v, 3,1)-RMD exists if and only ifv ≡ 0 or 1 (mod 3) andv ≠ 6. In this paper, it is shown that the necessary condition for the existence of a (v, 4, 1)-RMD, namelyv ≡ 0 or 1 (mod 4), is also sufficient, except forv = 4 and possibly exceptingv = 12. These constructions are equivalent to a resolvable decomposition of the complete symmetric directed graphK v * onv vertices into 4-circuits.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 4 (1988), S. 261-263 
    ISSN: 1573-2614
    Keywords: Anesthetics: sevoflurane ; Blood: hemoglobin ; Oxygen: tension ; Monitoring: oxygen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Fresh samples of heparinized human blood from 10 healthy nonsmoking volunteers were used to study the effect of the inhaled anesthetic sevoflurane on the oxygen half-saturation pressure of hemoglobin (P50) and on polarographic measurements of oxygen tension at low values. Control samples had a baseline P50 of 26.9±0.2 mm Hg. When the blood samples were exposed to 1.75% (1 minimum alveolar concentration, MAC), 2.75%, and 3.5% (2 MAC) of sevoflurane, the P50 values were 27.0±0.5 mm Hg, 27.1±0.4 mm Hg, and 26.9±0.5 mm Hg, respectively. Our present data show that 1 to 2 MAC sevoflurane has no significant effect on P50 (P〉0.05). Our data also show that sevoflurane did not interfere with polarographic measurements of oxygen tension (P〉0.05). Other inhaled agents—halothane, enflurane, and isoflurane—do interfere with these measurements, and we cannot explain the difference.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...