Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Gas chromatography-IR spectroscopy ; Propanediol ; Acyclovir
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple procedure is described for the determination of the 1,2-propanediol (propylene glycol) content of cream formulations containing the antiviral drug Acyclovir. Analysis of a solvent extract by gas chromatography coupled to an infra-red spectrometer enables the target analyte to be positively identified and an estimate of its concentration to be made. This application utilises the newer Tracer cryogenic deposition interface for gas chromatography and infra-red spectroscopy. This offers an alternative and complementary analytical strategy to gas chromatography coupled to mass spectrometry.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0197-8462
    Keywords: dielectric heaters ; body currents ; SARs ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Data are presented on ankle-specific SARs and foot currents as a function of strengths of radio-frequency electromagnetic fields encountered by operators of dielectric heaters. The determination of foot currents was based on near-field exposures in which reactive coupling dominates, and which can result in substantial SARs in exposed workers. The operators were located less than one wavelength from - usually within one meter of - the dielectric heaters, which generated fields at frequencies from 6.5 to 65 MHz. At distances normally assumed by workers, maximal strengths of electric fields ranged from 104 to 2.4 × 106 V2/m2; maximal strengths of magnetic fields ranged from 5.0 × 10-3 to 33.3 A2/m2. Currents through both feet to ground were measured while operators stood where they normally worked. Maximal currents ranged from 3 to 617 mA, rms. Nearly 27 percent of the dielectric heaters induced foot currents that exceeded the 200-mA limit that has been proposed for a new ANSI C95.1 standard. Twenty percent of the heaters induced foot currents that exceeded 350 mA. SARs in ankles were calculated from foot currents, and they approximated 5 W/kg at 100 mA, 29 W/kg at 250 mA, and 57 W/kg at 350 mA. The maximal SAR in the ankle was ∼ 176 W/kg at 617 mA. © 1992 Wiley-Liss, Inc.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...