Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Self-administration  (3)
  • Mechanical transducer  (2)
  • 1
    ISSN: 1433-0458
    Schlagwort(e): Schlüsselwörter TICA ; CT ; Ohr ; Schwerhörigkeit ; Wandler ; Kochleaverstärker ; Implantierbares Mikrofon ; Implantierbares Hörgerät ; Key words Ear ; Hearing loss ; TICA ; Hearing aid ; Mechanical transducer ; X-ray ; CT ; Cochlea amplifier implant
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Summary Recently, the transducer and microphone of a cochlea amplifier implant (CAI) for the treatment of sensorineural cochlear hearing loss have been developed further for implantation into the mastoid cavity. At present, the University of Tuebingen implantable cochlea amplifier consists of an implantable microphone and an implantable piezoelectric transducer. It has been implanted into the first patients. Successful future application of this new implant depends on the suitable fit of the CAI within a patient’s mastoid cavity. Using conventional X-ray and CT scans, we analyzed 50 cadaver specimens of the temporal bone before total mastoidectomy. After total mastoidectomy, the volume of the mastoid cavity was measured using CT scans and water volume determination. Finally, the CAI was implanted into those temporal bones that were large enough to house it. Our results demonstrate that the degree of pneumatization in the conventional Schüller X-ray is already a good parameter for preoperative evaluation.
    Notizen: Zusammenfassung Kürzlich wurden ein Mikrofon und ein Wandler eines intramastoidal implantierbaren Kochleaverstärkers (CAI) zur Hörrehabilitation bei cochleärer Schwerhörigkeit vorgestellt. Dieses System besteht aus einem implantierbaren Mikrofon und einem implantierbaren piezoelektrischen Wandler. Es wurde bei Patienten akut implantiert. Die für eine zukünftige Indikationsstellung wichtigen Fragen lauten: 1. ob die Mastoidhöhle eines jeweiligen Patienten ausreichend Platz für ein CAI bietet und 2. ob eine präoperative bildgebende Diagnostik prädiktive Parameter zur Implantationseignung liefern kann. An 50 menschlichen Felsenbeinen haben wir computertomografische (CT-)Aufnahmen und Röntgenaufnahmen nach Schüller durchgeführt und die Daten mit den Ergebnissen anschließender Probeimplantationen verglichen. Unsere Ergebnisse zeigen, daß der Grad der mittels Röntgenaufnahme nach Schüller ermittelten Pneumatisation der Warzenfortsatzzellen und der Zygomatikuszellen sowie die computertomographisch ermittelte Distanz zwischen Sinus sigmoideus und hinterer Gehörgangswand im CT wichtige Parameter zur präoperativen Beurteilung der Implantierbarkeit sind.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1433-0458
    Schlagwort(e): Schlüsselwörter Ohr ; Schwerhörigkeit ; TICA ; Implantierbares Hörgerät ; Mechanischer Transducer ; Implantierbares Mikrofon ; Key words Ear ; Hearing loss ; TICA ; Implantable hearing aid ; Mechanical transducer ; Implantable microphone
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Summary Recently, an implantable hearing aid for rehabilitation of sensorineural hearing loss has been developed. One component of the device is the microphone for implantation into the posterior canal wall. The membrane of the microphone can be covered by skin, cartilage, or fascia, avoiding reduction in sound transmission at the same time. In the study presented here, the microphone was implanted into 50 cadaver specimens of human temporal bone. Localization of the microphone was determined by the anatomical situation of the facial nerve. The microphone and the piezoelectric transducer could be implanted in 78% of the temporal bones after total mastoidectomy. In the final version of the microphone, the size was 4.5 mm and total weight 400 mg.
    Notizen: Zusammenfassung Implantierbare Hörgeräte für Innenohrschwerhörige benötigen einen implantierbaren Schallaufnehmer in oder hinter dem Trommelfell oder subkutan in der Gehörgangswand. Das Schwingungsverhalten des Trommelfells kann individuell und frequenzabhängig extrem unterschiedlich sein, während die Gehörgangshaut reproduzierbar schwingt. Deshalb wurde in einem Verbundprojekt ein vollständig implantierbares Mikrofon für die Implantation in die hintere knöcherne Gehörgangswand in einer Form realisiert, daß Haut, Knorpel oder Fascie auf der Mikrofonmembran zu keiner klinisch relevanten Schalldämpfung führen. In der vorliegenden Studie wurde an 50 Felsenbeinen der operationstechnisch zweckmäßigste Implantationsort für ein Mikrofon erarbeitet, der 1. ausreichend trommelfellnah ist, der 2. der Gehörgangshaut flach aufliegt und der 3. gleichzeitig die intramastoidale Implantation eines Wandlers erlaubt. Die Lokalisation wurde wesentlich durch den Verlauf des N. facialis bestimmt. Gleichzeitig wurden in einem iterativen Verfahren Form und Größe des Mikrofons schrittweise an die chirurgische Anatomie des Implantatsortes sowie an die Operationstechnik angepaßt. Es konnte eine Mikrofonform gefunden werden, die die Implantation des Mikrofons als Bestandteil eines implantierbaren Hörgeräts in einer funktionell und topographisch adäquaten Form bei gemeinsamer Implantation mit dem Wandler in 78% der Felsenbeine erlaubte. In dieser Endform hat das Mikrofon einen Durchmesser der schallaufnehmenden Membran von 4,5 mm sowie ein Gesamtgewicht von 0,4 g und ist zur Implantation bei den meisten Patienten geeignet.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1432-2072
    Schlagwort(e): Genetic basis of substance abuse ; Inbred strains ; Cocaine ; Self-administration ; Progressive-ratio ; Restriction fragment length polymorphisms ; Rats ; D1 receptor ; D2 receptor ; Dopamine ; SCH 23390 ; Eticlopride
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract This study investigated the influence of genetics on extent of cocaine taking in rats that were self-administering cocaine under a progressive-ratio schedule. Fischer 344, ACI and Brown Norway rats were subjects because previous genetic studies on dopamine receptor loci have indicated that these are genetically divergent strains. All subjects were assessed for acquisition and stability of cocaine self-administration under a progressive-ratio schedule. Subsequently, a dose-effect curve for cocaine self-administration was determined for each strain. Fischer 344 rats maintained a higher average breaking point than did the ACI or Brown Norway strains. In addition, dopamine receptor antagonists differentially reduced the ability of cocaine to serve as a reinforcer across the three strains. The D1-selective dopamine receptor antagonist, SCH 23390, and the D2/D3-selective dopamine receptor antagonist, eticlopride, were significantly more effective in reducing the self-administration of cocaine in Brown Norway rats than for the other two strains. The results of this study demonstrate that genetic differences may play an important role in determining responding under progressive-ratio schedules for cocaine, possibly due to differences in the reinforcing efficacy of cocaine.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1432-2072
    Schlagwort(e): Key words Genetic basis of substance abuse ; Inbred strains ; Cocaine ; Self-administration ; Progressive-ratio ; Restriction fragment length polymorphisms ; Rats ; D1 receptor ; D2 receptor ; Dopamine ; SCH 23390 ; Eticlopride
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  This study investigated the influence of genetics on extent of cocaine taking in rats that were self-administering cocaine under a progressive-ratio schedule. Fischer 344, ACI and Brown Norway rats were subjects because previous genetic studies on dopamine receptor loci have indicated that these are genetically divergent strains. All subjects were assessed for acquisition and stability of cocaine self-administration under a progressive-ratio schedule. Subsequently, a dose-effect curve for cocaine self-administration was determined for each strain. Fischer 344 rats maintained a higher average breaking point than did the ACI or Brown Norway strains. In addition, dopamine receptor antagonists differentially reduced the ability of cocaine to serve as a reinforcer across the three strains. The D1-selective dopamine receptor antagonist, SCH 23390, and the D2/D3-selective dopamine receptor antagonist, eticlopride, were significantly more effective in reducing the self-administration of cocaine in Brown Norway rats than for the other two strains. The results of this study demonstrate that genetic differences may play an important role in determining responding under progressive-ratio schedules for cocaine, possibly due to differences in the reinforcing efficacy of cocaine.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Psychopharmacology 147 (1999), S. 143-152 
    ISSN: 1432-2072
    Schlagwort(e): Key words D3 receptor antagonist ; Self-administration ; Fixed-interval schedule ; Rhesus monkey
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  Rationale: Based on the differential distribution of dopamine (DA) D3 receptors in mesolimbic regions relative to nigrostriatal regions, the hypothesis was that D3-selective antagonists (i.e., higher affinity at D3- than D2-receptors) would be more potent than D2-selective antagonists at decreasing total cocaine intake relative to disrupting rates of responding. Objective: To evaluate the effects of acute administration of seven DA antagonists with varying affinities for D2 and D3 receptors in monkeys self-administering cocaine. Methods: Rhesus monkeys were trained to self-administer intravenous cocaine (0.01–0.3 mg/kg per injection) under a fixed-interval (FI) 5-min schedule during daily 4-h sessions. The use of a FI schedule allowed for independent assessment of rate effects and changes in reinforcement frequency as a consequence of drug pretreatments. The compounds examined, in order of D3 binding affinity, were: 2,3-dimethoxy-N-(9-p-fluorobenzyl)-azabicyclo[3.3.1]nonan-3β-yl benzamide (MABN) = eticlopride = 5-bromo- 2,3-dimethoxy-N-[1-(4-fluorobenzyl)piperidin-4-yl]benz-amide (BBP) 〉 spiperone 〉 fluoroclebopride (FCP) 〉 2,3-dimethoxy-N-(p-fluorobenzyl)piperdin-4-yl benzamide (MBP) 〉 haloperidol. Results: In the absence of any pretreatments, cocaine-maintained responding varied as a function of dose and was characterized as an inverted U-shaped function, while cocaine intake increased in a dose-related fashion. When the dose of cocaine that maintained peak rates was available, all DA antagonists decreased response rates and cocaine intake in a dose- dependent manner. Increases in cocaine dose attenuated the effects of the DA antagonists, resulting in rightward shifts of the cocaine dose–response curves. Based on the ratio of behavioral potency at decreasing response rates relative to intake (ED50 rate/ED50 intake) when the highest cocaine dose was available, the order of potency and ED50 ratio values were: MABN (2.5) 〉 eticlopride (1.63) 〉 BBP = spiperone (1.5) 〉 FCP (1.35) 〉 MBP = haloperidol (0.89). This order parallels each compound’s affinity at D3 receptors (r 2=0.84) to a greater degree than D2 receptor affinity (r 2=0.34). Conclusions: These results, using a FI schedule of cocaine self-administration, suggest that D3 receptor antagonists are more likely to selectively decrease intake relative to response rates than D2 receptor antagonists.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...