Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 327-332 
    ISSN: 1612-1112
    Keywords: Supercritical fluid chromatography ; Semi-preparative chromatography ; Peak compression effect ; Dihydropyridine drug
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Peak compression of a dihydropyridine drug, clevidipine, is obtained in both analytical and semi-preparative scale supercritical fluid chromatography, resulting in extremely high apparent efficiencies. The observed effect, when utilising a carbon dioxide/2-propanol mobile phase with a bare silica stationary phase, is achieved when the retention of the clevidipine peak is controlled to coalesce with a system peak, generated as a result of having water in the sample. Apparent efficiencies of 350,000 and 170,000 plates meter−1 were obtained when 0.25 and 0.5 mg, respectively, are directly injected to a 200×4.6 mm ID 5 μm Hypersil silica packed column. The effect was extended to a semi-preparative system where apparent efficiencies in the region of 2,000,000 plates meter−1 were observed when 0.3 mg of a clevidipine sample containing 80% water was injected to a 250×10 mm I.D. column containing 5-μm Hypersil silica particles.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Supercritical fluid chromatography ; Peak compression ; Chemometrics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In this paper chemometrics have been used to study and characterize peak compression phenomena in packed column SFC. A carbon dioxide/2-methyl-1-propanol mobile phase was used in the experimental design (modifier concentration, temperature and pressure) and modelling part of the investigation. A cubic interaction term was needed in the model to obtain a reasonable fit, suggesting that all three parameters are of significance in terms of controlling peak compression. At the optimum conditions derived from the model a narrow peak was obtained as predicted.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...