Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Computational Chemistry and Molecular Modeling  (1)
  • Upper body  (1)
  •  Muscle power   (1)
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    European journal of applied physiology 73 (1996), S. 353-357 
    ISSN: 1439-6327
    Schlagwort(e): Upper body ; Muscle function ; Median frequency
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The purpose of this research was to perform isometric tests at two joint angles and examine their relationship to dynamic performance. In addition, electromyograph data were collected from the triceps brachii and pectoralis major muscles to compare underlying neural characteristics between the isometric tests and dynamic movement. A group of 24 healthy male subjects performed two isometric tests in a bench press position, at elbow angles of 90 and 120°. From these data, the maximal force and rate of force development were determined. In addition, each subject performed a seated medicine ball throw as a measure of dynamic upper body performance. Correlations showed that isometric measurements of force (r = 0.47–0.55) and rate of force development (r = 0.08–0.31) were poor predictors of dynamic performance. The angle of isometric assessment had little effect on the relationship between the tests and measurements of performance. The myo-electric data was processed in terms of the integrated electromyogram and the Fourier transformed frequency spectrum. These data demonstrated differences in the neural activation patterns of the musculature, between the isometric 90° test and the medicine ball throw. The poor relationship between isometric tests and medicine ball performance was consequently, at least partially, attributed to differing motor unit activation patterns between isometric and dynamic movement. The results of this research strongly suggest that isometric tests have limited value when assessing dynamic upper body performance.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1439-6327
    Schlagwort(e): Key words  Force velocity relationship  ;  Muscle power  ;  Electromyography  ;  Bench press
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Although explosive power in lower-body movements has been extensively studied, there is a paucity of research examining such movements in the upper body. This study aimed to investigate the influence of load and the stretch shortening cycle (SSC) on the kinematics, kinetics, and muscle activation that occurs during maximal effort throws. A total of 17 male subjects performed SSC and concentric only (CO) bench throws using loads of 15%, 30%, 45%, 60%, 75%, 90% and 100% of their previously determined one repetition maximum bench press. The displacement, velocity, acceleration, force and power output as well as the electromyogram (EMG) from pectoralis major, anterior deltoid, and triceps brachii were recorded for each throw. The results were compared using multivariate analysis of variance with repeated measures. A criterion alpha level of P ≤ 0.05 was used. Similar force velocity power relationships were determined for this multijoint upper-body movement as has been found for isolated muscles, single joint movements, and vertical jumping. The highest power output was produced at the 30% [563 (104) W] and 45% [560 (86) W] loads during the SSC throws. Force output increased as a function of load; however, even the lighter loads resulted in considerable force due to the high accelerations produced. Average velocity, average and peak force, and average and peak power output were significantly higher for the SSC throws compared to the CO throws. However, peak velocity and height thrown were not potentiated by performing the pre-stretch because the duration and range of movement allowed the ability of the muscle to generate force at high shortening velocities to dominate the resulting throw. As such, explosive movements involving longer concentric actions than experienced during brief SSC movements may be limited by the ability of the muscle to produce force during fast contraction velocities.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Computational Chemistry 5 (1984), S. 427-440 
    ISSN: 0192-8651
    Schlagwort(e): Computational Chemistry and Molecular Modeling ; Biochemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Informatik
    Notizen: The force constants and compliance constants of methyl, silyl, and germyl fluoride, chloride, bromide, and iodide have been calculated by the iterative consistency method. Using the force fields so obtained, centrifugal distortion constants, Coriolis coupling constants, and mean amplitudes of vibration have been computed and compared with experimental data, where available.
    Zusätzliches Material: 8 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...