Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (2)
  • Binomial Distribution  (1)
  • obstructive airways disease  (1)
Material
Years
  • 1980-1984  (2)
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Computing 25 (1980), S. 193-208 
    ISSN: 1436-5057
    Keywords: Random Numbers ; Binomial Distribution ; Poisson Distribution ; Simulation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science
    Description / Table of Contents: Zusammenfassung Ein exakter Verwerfungsalgorithmus wird konstruiert und ausgetestet. Das Verfahren erfordert durchschnittlich weniger als 3 gleichverteilte Zufallszahlen, solange die Standardabweichung σ der Verteilung mindestens 4 beträgt; diese Anzahl fällt monoton gegen 2,63 für σ→∞. Variable Parameter sind zugelassen; es werden keinerlei Unterprogramme für Stichproben von anderen statistischen Verteilungen benötigt.
    Notes: Abstract An accurate acceptance-rejection algorithm is devised and tested. The procedure requires an average of less than 3 uniform deviates whenever the standard deviation σ of the distribution is at least 4, and this number decreases monotonically to 2.63 as σ→∞. Variable parameters are permitted, and no subroutines for sampling from other statistical distributions are needed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 417-422 
    ISSN: 1432-1041
    Keywords: theophylline ; aminophylline ; obstructive airways disease ; short-term i.v. infusion ; log-normal distribution ; pharmacokinetics ; serum concentrations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Serum theophylline concentrations after intravenous administration of a new short-term infusion (Euphyllin® Kurzzeitinfusion) were measured in 50 out-patients with chronic obstructive airways disease (COAD). An intravenous infusion of theophylline ethylenediamine 480 mg (corresponding to approximately 350 mg anhydrous theophylline) in 50 ml isotonic solution was given in 20 min. Blood samples were taken beforehand and 25 to 30 min and 1, 3 and 6 h after starting the infusion. 86% of the patients had a one-hour serum level in the therapeutic range of 8–20 mg/l, and 2 h later, this was true of 64% of the patients. The short-term infusion was well tolerated, even in cases with unknown high pre-infusion serum levels. Pertinent pharmacokinetic parameters were determined, such as total body clearance, apparent volume of distribution, and half-life of elimination. Geometric mean and 95%-confidence limits, derived from the log-normal distribution of these parameters, were: Cl=0.044 (0.018–0.109) l/h/kg ideal body weight, Vd=0.451 (0.258–0.789) l/kg ideal body weight, and t1/2(el)=7.1 (2.6–19.1) h.
    Type of Medium: Electronic Resource