Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (1)
  • operating microscope  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 69 (1988), S. 11-18 
    ISSN: 1573-2622
    Keywords: photic retinopathy ; posterior chamber lens ; operating microscope
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Three patients presented a characteristic retinopathy presumbly induced by light arising from operating microscope during extracapsular cataract extraction combined with intraocular lens insertion. The operating microscope was equipped with video-recorder. Light sources were tungsten bulb. All cases were asymptomatic and an inspection at the post-operative control examination led to the detection of this type of retinopathy.