Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 35 (1997), S. 1261-1267 
    ISSN: 0887-6266
    Keywords: FTIR-ATR spectroscopy ; gravimetric sorption ; diffusion ; polymer ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: In this study, vapor sorption FTIR-ATR (Fourier Transform Infrared Attenuated Total Reflectance) spectroscopy was combined with a conventional gravimetric sorption balance to examine diffusion in polymers. Mutual diffusion coefficients of methyl ethyl ketone in polyisobutylene were measured using both methods at various penetrant activities and temperatures in the range 40-60°C. Actual penetrant concentrations were determined from the sorption balance. The diffusion coefficients from the two techniques agree very well with each other. In addition, the diffusivity data from both techniques could be correlated successfully as a function of temperature and concentration with the Vrentas and Duda free-volume model. © 1997 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 35: 1261-1267, 1997
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 337-344 
    ISSN: 0887-6266
    Keywords: infrared spectroscopy ; multicomponent ; diffusion ; polymer ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: In this study, diffusion coefficients of toluene/methyl ethyl ketone (MEK) mixtures in polyisobutylene were measured at 50°C using vapor sorption FTIR-ATR (Fourier Transform Infrared Attenuated Total Reflectance) spectroscopy. For three mixture compositions, the diffusion coefficients were determined using a diffusion framework for ternary systems. The “crossterm” diffusion coefficient for MEK was found to be very small under the experimental conditions studied here, while that for toluene was found to increase with increasing MEK concentration. On the basis of this finding, a binary diffusion model was used to determine diffusion coefficients for MEK over a wide range of mixture compositions and the results compared well with those determined from pure MEK transport data. Relative transport rates during integral sorption experiments with mixtures were used to explain the results. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 337-344, 1998
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...