    Analog integrated circuits and signal processing 14 (1997), S. 249-260 
    ISSN: 1573-1979
    Keywords: transducer interface ; smart sensor system ; smart sensor interface ; bridge interface ; captive interface ; universal transducer interface
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Abstract This paper presents a new universal transducer interface.This interface, which is read out by a microcontroller, servicesthe following sensor elements: capacitors, platinum resistors,thermistors, resistive bridges and potentiometers. The A/D conversionis based on a first-order oscillator. A combination of classicaland some new measurement techniques has been applied on a singlechip to obtain high accuracy, good long-term stability and areduction of the effects of interference and parasitic elements.The circuit has been fabricated in a 0.7 µm CMOSprocess. The main test results are: an accuracy of 10–15bits and a resolution up to 16 bits while the measurement timeis in the range 1–100ms. These results hold over the temperaturerange −20°C to 80°C. Calibrationof the electronic part is not required. The number of externalcomponents has been kept to a minimum.