  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 4282-4285 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The methodology for accurately calibrating the Niobe resonant-mass gravitational wave detector is presented. The transducer is based on a low noise resonant microwave cavity transducer that converts the displacement of the resonating mass to microwave energy. The calibration technique consists of a one off measurement of the microwave frequency versus resonant-mass displacement characteristic. To measure this accurately, known static forces were applied to the resonant mass and the change in the transducer microwave frequency was recorded. With the aid of finite element analysis and accurate measurements of the resonant-mass characteristics, the deflection due to the known force was calculated. The calculated deflections were verified coarsely with measurements from a calibrated linear variable differential transformer. Typically, the detector operates with a 1 mK noise temperature. A best noise temperature of 890 μK between 1300 and 2000 Universal Time Coordinate (UTC) for day 60 in 1997 is reported. The transducer has been upgraded with a new microwave amplifier, which has a measured electronic noise floor 40 dB lower than the previous amplifier, which is only 10 dB above the quantum limit. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Inc
    Wound repair and regeneration 8 (2000), S. 0 
    ISSN: 1524-475X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In a healing wound, inflammatory cells undergo apoptosis immediately beneath the leading edge of migrating epithelium. A potential mediator of this apoptosis pattern is p53, a protein with antiproliferative effects. Another protein, bcl-2, is antagonistic to p53 and prevents apoptosis. The purpose of this study was to determine the expression and location of p53 and bcl-2 mRNA and protein in healing wounds of normal and genetically diabetic mice. At various time points, full-thickness skin wounds from nondiabetic and diabetic mice were evaluated for p53 and bcl-2 by immunohistochemistry and in situ hybridization. Apoptosis patterns were also determined using the TUNEL method. Messenger RNA for p53 and bcl-2 were quantitated by competitive reverse transcriptase-polymerase chain reaction. Protein and mRNA for p53 were expressed in the leading edge of migrating epithelium, with apoptosis patterns closely following those of p53 production. p53 mRNA levels decreased soon after wounding, but after a few days, levels increased to greater than baseline. bcl-2 was localized to the wound epithelium, but relative amounts tended to oppose levels of p53, i.e, when p53 increased, bcl-2 decreased and vice versa. Wounds in diabetic animals showed a delayed onset of p53 mRNA expression but had persistently greater levels for longer periods of time. bcl-2 mRNA expression was further delayed in diabetic mice and did not develop to levels as high as p53. Production of both proteins was delayed, consistent with the mRNA expression. Our data show that immediately after wounding, bcl-2 increases and p53 decreases to allow for the cellular proliferation that is required for tissue repair. Over time, bcl-2 levels decrease while p53 levels increase to shut down the inflammatory process and down-regulate the proliferative response. Diabetic animals appear to lose the indirect relationship between p53 and bcl-2. This loss may contribute to the altered apoptosis patterns observed in diabetic healing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 11 (2000), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1471-4159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: Recent data from our laboratory have shown a regionally specific increase in lipid peroxidation in postmortem progressive supranuclear palsy (PSP) brain. To extend this finding, we measured activities of mitochondrial enzymes as well as tissue malondialdehyde (MDA) levels in postmortem superior frontal cortex (Brodmann’s area 9; SFC) from 14 pathologically confirmed cases of PSP and 13 age-matched control brains. Significant decreases (-39%) in α-ketoglutarate dehydrogenase complex/glutamate dehydrogenase ratio and significant increases (+36%) in tissue MDA levels were observed in the SFC in PSP; no differences in complex I or complex IV activities were detected. Together, these results suggest that mitochondrial dysfunction and lipid peroxidation may underlie the frontal metabolic and functional deficits observed in PSP.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 88 (2000), S. 6317-6320 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Thermal conductivities Λ of amorphous carbon thin films are measured in the temperatures range 80–400 K using the 3ω method. Sample films range from soft a-C:H prepared by remote-plasma deposition (Λ=0.20 W m−1 K−1 at room temperature) to amorphous diamond with a large fraction of sp3 bonded carbon deposited from a filtered-arc source (Λ=2.2 W m−1 K−1). Effective-medium theory provides a phenomenological description of the variation of conductivity with mass density. The thermal conductivities are in good agreement with the minimum thermal conductivity calculated from the measured atomic density and longitudinal speed of sound. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1469-8986
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Psychology
    Notes: Effects of nicotine and caffeine, separately and in combination, were assessed in 12 male habitual smokers in a repeated-measures design. Caffeine (0-mg vs. two 150-mg doses administered in a decaffeinated/sugar-free cola drink post-baseline and 90 min later) was crossed with nicotine (ad libitum own dosing vs. 1.0-mg machine-delivered dose vs. 0.05-mg machine-delivered dose). Participants smoked a total of five cigarettes at 30-min intervals over a 2-hr period. Caffeine and nicotine had large effect sizes on electroencephalogram (EEG) power; however, these effects were modulated by the eyes open versus closed condition, the other drug, and electrode site. EEG effects of open versus closed eyes tended to be of the same size and direction as those of nicotine and caffeine. However, whereas nicotine increased EEG power in some higher frequency bands in some conditions, caffeine decreased EEG power across almost all conditions. Serum cortisol concentration, vigor, and pleasantness were increased by nicotine, but not by caffeine. Level of depressive mood depended on an interaction of caffeine and nicotine. Vigilance performance was enhanced significantly by caffeine and was increased almost significantly by nicotine. The findings were interpreted in terms of common and differential mechanisms of the two drugs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK and Boston, USA : Blackwell Publishers Ltd
    Economic affairs 20 (2000), S. 0 
    ISSN: 1468-0270
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Economics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Economic affairs 20 (2000), S. 0 
    ISSN: 1468-0270
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Economics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Economic affairs 20 (2000), S. 0 
    ISSN: 1468-0270
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Economics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK and Boston, USA : Blackwell Publishers Ltd
    Economic affairs 20 (2000), S. 0 
    ISSN: 1468-0270
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Economics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...