Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Key words: Angioma, gastrointestinal tract—Liver, MR—Liver neoplasms, MR—Magnetic resonance (MR), comparative studies—Magnetic resonance (MR), technique.  (1)
  • 1
    ISSN: 1432-0509
    Schlagwort(e): Key words: Angioma, gastrointestinal tract—Liver, MR—Liver neoplasms, MR—Magnetic resonance (MR), comparative studies—Magnetic resonance (MR), technique.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. Background: We compared T2-weighted and heavily T2-weighted breath-hold turbo spin-echo (TSE) sequences with T2-weighted non-breath-hold TSE sequence to evaluate hepatic hemangiomas on magnetic resonance (MR) with a phased-array multicoil. Methods: Twenty-two patients with 27 hemangiomas were studied at 1.0-T scanner by using T2-weighted and heavily T2-weighted breath-hold TSE sequences (18 s each) and non-breath-hold T2-weighted TSE sequences with use of a phased-array multicoil. Images were quantitatively analyzed for tumor-to-liver signal-difference-to-noise ratios (SD/Ns) and tumor-to-liver signal intensity ratios (T/Ls) and qualitatively analyzed for tumor conspicuity and motion-induced image artifacts. Results: Quantitatively, T2-weighted breath-hold TSE images showed the highest SD/Ns among the three sequences, although the differences from the heavily T2-weighted breath-hold TSE sequence and the T2-weighted non-breath-hold TSE sequence were not statistically significant (p= 0.61 and 0.06, respectively). Heavily T2-weighted breath-hold TSE images showed the highest T/Ls among the three sequences. The differences from the T2-weighted breath-hold TSE sequence and the T2-weighted non-breath-hold TSE sequence were statistically significant (p 〈 0.001). Qualitatively, breath-hold TSE images were superior to non-breath-hold TSE images in terms of tumor conspicuity (p 〈 0.01) and motion artifacts (p 〈 0.01). Conclusion: T2-weighted breath-hold TSE sequence is superior to T2-weighted non-breath-hold TSE sequence in the evaluation of hepatic hemangiomas on MR with a phased-array multicoil.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...