Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Alpha-1-microglobulin  (1)
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Journal of molecular medicine 63 (1985), S. 711-717 
    ISSN: 1432-1440
    Schlagwort(e): Alpha-1-microglobulin ; Beta-2-microglobulin ; Proteinuria ; Renal insufficiency
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Alpha-1-microglobulin (alpha-1-m) is a low molecular weight glycoprotein (mw 25–33 KD) that is filtered through the glomeruli and reabsorbed in the proximal parts of the renal tubules where it is catabolized. Normal ranges were established for alpha-1-m (100 healthy controls) in serum (20–42 mg/l) and urine (3.5–8 mg/l). Alpha-1-m was then measured in 341 urine samples whose protein pattern had been classified as “pathologic” and “normal” according to microelectrophoresis. Increased alpha-1-m concentrations were found in 266 out of 280 pathologic urines (5% false negative) and in 3 out of 61 normal urines (4% false positive). Beta-2-microglobulin (beta-2-m), total protein or protein test strips showed a poorer correlation to the electrophoretic results. Measurement of alpha-1-m is, therefore, the most sensitive of these methods for the detection of proteinuria. In 90 patients with low molecular weight proteinuria and either with or without renal insufficiency alpha-1-m concentrations were determined in both urine and serum. While all patients had elevated urinary alpha-1-m concentrations, increased serum values were only found in renal insufficiency (Ccrea〈100 ml/min). Independently of these results, we were also able to establish that increased alpha-1-m levels are found at decreased glomerular filtration rates (Ccrea 〈70 ml/min). Pathologic alpha-1-m concentrations therefore only allow the conclusion of isolated tubular impairment when the GFR is greater than 70 ml/min. Data from 350 patients with various renal and hypertensive diseases showed that serum alpha-1-m is a more sensitive indicator of renal insufficiency, even in the so-called “creatinine blind” range (60–100 ml/min) of the GFR than either creatinine or beta-2-m.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...