Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 60 (2005), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary Twelve volunteers known to have airways that responded adversely to 2.0 MAC desflurane were recruited. Each volunteer inhaled three single breaths of each of 0.5, 1.0 and 2.0 MAC of sevoflurane, halothane, isoflurane, desflurane and balance air, with breaths of air between, whilst breathing nasally through a face mask attached to one of three filters that provided three different levels of humidification. The incidence of any adverse airway events was recorded. The anaesthetic inhaled significantly affected the incidence of adverse airway events (p 〈 0.001), with the least to most irritant being sevoflurane, halothane, isoflurane and desflurane. Increasing the concentration of anaesthetic also significantly increased the incidence of adverse airway events (p 〈 0.001). The filter used, and hence the level of humidification, did not affect the incidence of adverse airway events (p = 0.09), but repeated exposure caused a significant reduction in the incidence of adverse airway events (p 〈 0.001).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary Accidental oesophageal intubation is still an important cause of anaesthetic morbidity and mortality. This study investigated the use of impedance respirometry to determine the position of a tracheal tube. Seventy-nine patients undergoing general anaesthesia requiring tracheal intubation with muscle relaxation were recruited to the study. After pre-oxygenation, tracheal tubes were placed in both the oesophagus and trachea; a breathing system was attached to one tube chosen randomly. A blinded observer was required to correctly identify the position of the tube within six tidal ventilations. The position of every tube connected to the breathing system was correctly identified. The median time to correctly identify tracheal and oesophageal tubes was 3 and 5 s, respectively. The median number of breaths to identify tracheal and oesophageal tubes was two for both groups. Every tube position was identified within the required six breaths. Impedance respirometry is a reliable method for diagnosing tracheal tube position.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 60 (2005), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The Cardiff paediatric laryngoscope blade is a single blade that has been designed for use in children from birth to adolescence. This open, randomised, crossover study compared the Cardiff blade with the straight, size 1, Miller laryngoscope blade in 39 infants under 1 years of age and the curved, size 2, Macintosh blade in 39 children aged 1–16 years. The same laryngoscopic view was obtained with the Cardiff and Miller blades in 26 patients; the view was better with the Cardiff blade in seven patients and better with the Miller blade in six (median (IQR [range]) grade of laryngoscopy 1 (1–2 [1–3]) vs. 1 (1–2 [1–3]), respectively; p = 0.405). The Cardiff blade was faster at gaining a view than the Miller blade (mean (SD) time 8.5 (2.9) s vs. 10.2 (3.5) s, respectively; 95% CI for difference −2.8 to −0.4; p = 0.009). The Cardiff and Macintosh blades produced the same view in 32 patients; the view was better with the Cardiff blade in seven patients (median (IQR [range]) grade of laryngoscopy 1 (1–1 [1–3]) vs. 1 (1–2 [1–3]), respectively; p = 0.008). There was no difference in time to gain these views: mean (SD) 8.7 (3.0) s vs. 9.3 (2.7) s, respectively (95% CI for difference −1.58 to 0.40; p = 0.237). The Cardiff paediatric laryngoscope blade compares favourably with these two established laryngoscope blades in children.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary The concern that re-usable equipment may be a source of cross-infection has prompted the increased use of disposable laryngoscope blades. We conducted a study investigating the duration of laryngoscopy and the peak force generated using various laryngoscope blades. Five blades were studied: one reusable Macintosh 3 blade, one disposable metal blade and three plastic disposable blades. Sixty anaesthetists performed laryngoscopy on a mannequin using each of the five blades presented in a random order. This was then repeated with a rigid collar applied to the mannequin. The mean force applied with the collar off with the metal blades was 32.8 and 30.8 N, and with the plastic blades 37.3, 39.6 and 41.5 N, respectively (p 〈 0.0001). The mean force applied with the collar on with the metal blades was 30.5 and 32.5 N, and with the plastic blades 35.5, 34.9 and 31.4 N, respectively (p 〈 0.0001). The mean duration of laryngoscopy with the collar off for the metal blades was 5.6 and 5.4 s, and with the plastic blades 10, 7.2 and 7.5 s (p 〈 0.0001). The duration of laryngoscopy with the collar applied for the metal blades was 7.1 and 7.5 s, and with the plastic blades 11.8, 9.7 and 9.0 s (p 〈 0.0001). The use of plastic blades results in both greater peak force and duration of laryngoscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 59 (2004), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Sevoflurane is a non-pungent volatile anaesthetic agent with a low blood-gas solubility coefficient. It has been studied in concentrations of up to 8% for induction of anaesthesia. Previous work has suggested that there may be a ceiling effect with increasing concentration of sevoflurane above 6%, but there are no published studies using 12% sevoflurane. This study compared 8 and 12% sevoflurane to induce anaesthesia in adults. Sevoflurane was administered using two adapted datum vaporisers with the interlock removed. Induction with 12% sevoflurane compared to 8% sevoflurane produced a significant decrease in the time to achieve central pupils, corresponding to surgical anaesthesia and the third part of Guedel's stage 3 of anaesthesia (mean time (SD) 201 s (81) and 247 s (39), respectively, p 〈 0.05). Twelve-percent sevoflurane produced a similar stable cardiovascular profile to 8% sevoflurane, and there was no increase in respiratory complications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 57 (2002), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Where practicable, exposure to a hazardous substance should be eliminated or adequately controlled. A postal questionnaire survey was sent to 10% of consultants from the Association of Anaesthetists of Great Britain and Ireland, to identify the level of use of nitrous oxide in current anaesthetic practice and identify any change of practice over the last 5 years. Details of anaesthetic practice were requested in three areas: nitrous oxide usage, availability of medical air on anaesthetic machines and the use of total intravenous anaesthesia. Replies were received from 320 consultants (75%). Of these, 49% felt that, over the last 5 years, their use of nitrous oxide had decreased. Twenty per cent of anaesthetists felt that there should be some restriction in availability of nitrous oxide. Where medical air was available, 32% felt that they would use it frequently. A total of 263 (83%) stated that they use total intravenous anaesthesia to some extent. The results showed that, although 49% of consultant anaesthetists had reduced their use of nitrous oxide, this was due to medical considerations rather than concerns over health and pollution issues arising from the use of nitrous oxide.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In the United Kingdom, cricoid force is central to upper airway management in obstetric and emergency anaesthesia. A reduction in oesophageal barrier pressure (OBP) in these patients may increase regurgitation risk. This study investigated whether the application of cricoid force to anaesthetised patients reduced lower oesophageal sphincter pressure (LOSP) and consequently OBP. Anaesthesia was induced in 29 patients using a standard protocol. An oesophageal balloon catheter was inserted and gastric trace identified. The catheter was withdrawn incrementally and pressure readings recorded at each position before and during the application of 30 N cricoid force, with a sudden rise in pressure indicating lower oesophageal sphincter position. Oesophageal barrier pressure was calculated as the difference between LOSP and gastric pressure. Application of cricoid force significantly reduced OBP without influencing gastric pressure (p 〈 0.001). The use of cricoid force may increase the risk of gastroesophageal reflux in anaesthetised patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 60 (2005), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We compared two manoeuvres, jaw thrust and laryngoscopy, to open the airway during fibreoptic intubation in 50 patients after induction of anaesthesia in a crossover study. Patients were randomly allocated to receive either jaw thrust or conventional Macintosh laryngoscopy first. Airway clearance was assessed at both the soft palate and the epiglottis. Direct laryngoscopy provided significantly better airway clearance at the level of the soft palate than jaw thrust (44 (88%) vs 31 (62%), respectively; p = 0.002). At the level of the larynx, airway clearance was equally good in both groups (45 (90%) vs 46 (92%), respectively; p = 0.56). The times to view the larynx (median (interquartile range [range]) 4 (3–5 [2–35]) s vs 3 (3–4 [2–8]) s, respectively) and intubation time (20 (17–23 [11–83]) s vs 18 (15–20 [11–28]) s, respectively) were also similar.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...