Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Chemistry  (21)
  • Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm  (2)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 1136-1139 
    ISSN: 1432-2218
    Schlagwort(e): Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Background: Laparoscopic surgery decreases postoperative pain and length of hospital stay. Whether laparoscopically assisted abdominal aortic aneurysm (AAA) repair can be safely and reliably performed is unknown. This prospective study was designed to establish the feasibility of laparoscopically assisted AAA repair and its effects on intraoperative and postoperative variables. Methods: With IRB approval, 10 patients with infrarenal AAA requiring a tube graft underwent laparoscopically assisted AAA repair. The procedure consisted of laparoscopic dissection of the aneurysm neck and iliac vessels. Then, through an 8–11-cm minilaparotomy, a standard endoaneurysmorrhaphy was performed. Data included laparoscopic and total operative times, blood loss, fluid requirements, duration of nasogastric suction (NGT), and lengths of intensive care unit (ICU) and postoperative hospital stays. Results: Laparoscopically assisted AAA was completed in nine of 10 patients. The first patient was converted to a standard incision because the aneurysm neck could not be adequately dissected. Laparoscopic and total operative times were 1.8 ± 0.4 and 4.5 ± 0.7 h, respectively. Mean blood loss was 1 ± 0.6 l. Intraoperative fluid requirement was 6.6 ± 1.3 l. The duration of NGT suction was 1.8 ± 1.0 days. The ICU stay was 2.1 ± 0.8 days and hospital stay was 6.7 ± 2.5 days. There were two minor complications and no deaths. Conclusions: Laparoscopically assisted AAA repair is technically feasible with acceptable blood loss, operative time, morbidity, and mortality. Potential advantages may be early removal of the NGT and shorter ICU and hospital stays. Prospective randomized trials are needed to determine if laparoscopically assisted AAA repair is advantageous.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-2218
    Schlagwort(e): Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Background: Advanced laparoscopic procedures are more commonly performed in elderly patients with cardiac disease. There has been limited data on the use of pulmonary artery catheters (PAC) and transesophageal echocardiography (TEE) to monitor hemodynamic changes. Methods: We prospectively studied eight patients undergoing laparoscopic assisted abdominal aortic aneurysm repair. All patients had a PAC and all but one had an intraoperative TEE. Data included heart rate (HR), temperature (temp), pulmonary artery systolic (PAS) and diastolic (PAD) pressures, mean arterial pressure (MAP), central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), cardiac index (CI), mixed venous oxygen saturation (MVO2), and oxygen extraction ratio (O2Ex) and was obtained prior to induction, during insufflation, after desufflation, during aortic cross-clamp, and at the end of the procedure. End diastolic area (EDA), a reflection of volume status, was measured on TEE. ANOVA was used for data analysis. Results: No changes were noted in HR, temp, PAS, PCWP, CI, MVO2, and O2Ex. PAD and CVP were greater during insufflation compared with baseline and aortic cross-clamp without associated changes in EDA. MAP was higher at baseline compared with all other times during the procedure. Conclusions: Insufflation increased PAD and CVP. However, volume status as suggested by EDA and PCWP did not change. These data question the reliability of hemodynamic measurements obtained from the PAC during pneumoperitoneum and suggest that TEE may be sufficient for evaluation of volume status along with the added benefit of timely detection of ventricular wall motion abnormalities.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 49 (1993), S. 1197-1203 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: This study was to improve the performances of nylon 4 membranes for washing waste-water treatment of nuclear power plants, e.g., removal of detergent and salt by membranes. The effects of the degree of grafting and ionization on the reverse osmosis performances of acrylic acid (AA)-grafted nylon 4 membranes by γ-ray irradiation modification were investigated. The relationships of operating conditions, such as feed concentrations of salt and detergent, operating temperature, and pressure, and the performances of water flux and solute rejection of the prepared membranes were obtained. Water flux of the prepared membranes was highly sensitive with the operating temperature. It was found that an increase in the operating pressure could increase the water flux and the impaction effect directly. Water flux and salt rejection were significantly improved by both ionized and nonionized AA-grafted nylon 4 membranes compared to ungrafted nylon 4 membranes. Water flux increased rapidly and solute rejection dropped off slightly as the grafted membranes were ionized. The 100% detergent rejection could be obtained by the nonionized AA-grafted nylon 4 membranes with 38.6 and 69.6% degrees of grafting under various operating conditions. Results obtained showed that these modified nylon 4 membranes were usable for washing waste-water treatment of nuclear power plants. © 1993 John Wiley & Sons, Inc.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 51 (1994), S. 1861-1874 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: Carbon-13 spin-lattice relaxation rates (1/T1) and nuclear Overhauser enhancement (NOE) measurements were performed on poly(4-methyl-1-pentene) above the glass transition temperature in order to explain the segmental motion of the molecule by means of high resolution nuclear magnetic resonance spectroscopy. Experiments were carried out for poly(4-methyl-1-pentene) with low, medium, and high molecular weights. The similarity of the T1 values showed that for polymers with a degree of polymerization (DP) 〉 100 the relaxation behavior of the carbon atoms no longer depends on molecular weight. The temperature effects were studied at 358, 363, 373, 383, 393, and 403 K, both on 25.18 and 100.61 MHz magnetic fields. Finally, several mathematical T1 models were applied to study the change of T1 encountered by the individual carbon atoms. The results reveal that the more factors being considered in the calculation the more consistent will be the results obtained with the T1 model. A comparison showed that parameters used in the DLM T1 model gives the best fit. © 1994 John Wiley & Sons, Inc.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 61 (1996), S. 1479-1486 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: In this paper, the blends of the carbon dioxide copolymer, poly(propylene carbonate) (PPC), with nitrile rubber (NBR) were studied by DSC, DMA, TEM and TG. PPC can enhance the mechanical properties of NBR, while oil resistance and tensile set at break of NBR/PPC systems were as good as that of NBR. The coagent of triallylisocyanurate or maleic anhydride with carbon black can much improve the curing efficiency of dicumyl peroxide in NBR/PPC systems. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 60 (1996), S. 1569-1574 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The curing characteristics of unaccelerated sulfur vulcanization of ENR 25 and ENR 50 were studied in the temperature range from 100-180°C. The range of sulfur loading was from 1.5 to 6.5 phr. The scorch time was determined by Mooney Shearing Disk Viscometer whereas the initial cure rate, maximum torque, and reversion properties were obtained from the Moving Die Rheometer (MDR 2000). Results shows that ENR 25 gives a longer scorch time than ENR 50, an observation similar to that in an accelerated system reported earlier. For temperature 〈 120°C, scorch time depends exponentially on sulfur loading for both rubbers. However, this dependence diminishes as temperature is increased. This observation is attributed to the availability of activated sulfur molecules for vulcanization. The initial cure rate and maximum torque increases with increasing sulfur loading. ENR 50, however, exhibits higher value than ENR 25, suggesting faster cure in the former. For a fixed sulfur loading, reversion is a time and temperature-dependent phenomenon. It decreases with increasing sulfur loading because of the increase of cross-linking density for both rubbers stuided. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 40 (1990), S. 1053-1057 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 46 (1992), S. 489-498 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: To enhance the degree of grafting, homografting copolymerization of 2-hydroxyethyl methacrylate (HEMA) onto nylon 4 using a chemical initiator has been attempted. The factors that affect the grafting copolymerization are the concentration of reactants, reaction time, and temperature. The dialysis permeabilities of solutes, water content, surface energy, mechanical properties, and blood compatibility of the membrane were investigated. Under the same reaction conditions, the degree of grafting by the homografting method is remarkably higher than of the heterografting method for the nylon 4-HEMA grafting system. The dialysis permeabilities of NaCl, vitamin B12, and ovalbumin of the homografted membrane with a 14.8% degree of grafting are 2.760, 0.392, and 0.073 × 10-5 cm2/min, respectively. These permeabilities are higher than the corresponding ones of ungrafted nylon 4 membrane. The mol ratios of adsorbed fibrinogen/albumin (F/A) of the heterografted membranes were found to decrease from 0.53 to 0.33, and the surface energy, to increase from 40.6 to 46.4 dyn/cm with the degree of grafting in the range of 12.5-29.9%, and their relationship is not remarkable for the homografted membranes for which the mol ratios of F/A are about 0.22-0.32 with the degree of grafting in the range of 14.8-103.8%. Observed from scanning electron micrographs of the membrane surface, denseness was found to be important to improve blood compatibility. Based on the dialysis permeabilities of solutes and the blood compatibility observed in this study, the homografted nylon 4/HEMA membrane can be considered as a hemodialysis material.
    Zusätzliches Material: 13 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 17 (1973), S. 789-796 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The permeation properties of formalized poly(vinyl alcohol) membranes are described. The interest of this work is centered on the properties relevant to desalination by reverse osmosis. These membranes, when properly prepared, showed reasonably high water permeability, high salt rejection, and stability in the presence of acids and alkalies.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The change in the concentration of sodium dodecyl sulfate (SDS) can, in fact, affect directly the correlation between phase behavior and structure of a four-component system, polyethylene glycol/sodium dodecyl sulfate/pentanol/H2O. Experimental results indicate that the phenomena of microemulsion and lamellar liquid crystals can take place at a concentration of SDS greater than 5% and 17% by weight, respectively. In our experiments, these liquid crystals are tested and found to be hydrophilic and their rheological properties to be non-Newtonian as well.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...