Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2022-03-14
    Description: Deutsche Bahn (DB) operates a large fleet of rolling stock (locomotives, wagons, and train sets) that must be combined into trains to perform rolling stock rotations. This train composition is a special characteristic of railway operations that distinguishes rolling stock rotation planning from the vehicle scheduling problems prevalent in other industries. DB models train compositions using hyperarcs. The resulting hypergraph models are ad-dressed using a novel coarse-to-fine method that implements a hierarchical column genera-tion over three levels of detail. This algorithm is the mathematical core of DB’s fleet em-ployment optimization (FEO) system for rolling stock rotation planning. FEO’s impact within DB’s planning departments has been revolutionary. DB has used it to support the company’s procurements of its newest high-speed passenger train fleet and its intermodal cargo locomotive fleet for cross-border operations. FEO is the key to successful tendering in regional transport and to construction site management in daily operations. DB’s plan-ning departments appreciate FEO’s high-quality results, ability to reoptimize (quickly), and ease of use. Both employees and customers benefit from the increased regularity of operations. DB attributes annual savings of 74 million euro, an annual reduction of 34,000 tons of CO2 emissions, and the elimination of 600 coupling operations in cross-border operations to the implementation of FEO.
    Language: English
    Type: article , doc-type:article
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of organic chemistry 56 (1991), S. 575-580 
    ISSN: 1520-6904
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of medicinal chemistry 25 (1982), S. 1451-1454 
    ISSN: 1520-4804
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of medicinal chemistry 31 (1988), S. 230-243 
    ISSN: 1520-4804
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of medicinal chemistry 28 (1985), S. 1716-1720 
    ISSN: 1520-4804
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 95 (1991), S. 4343-4359 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: We report ab initio calculations of the ground state energy for 404 new conformations of H3, supplementing the set of 368 conformations reported previously by others. The entire dataset has been used to constrain an analytical functional form for the potential energy surface, building on that of Truhlar and Horowitz. The new surface extends the Truhlar and Horowitz surface to higher energies and offers some modest improvement at lower energies. In addition, we have eliminated a problem with derivatives of the London equation that was pointed out by Johnson. The new surface matches the 772 ab initio energies with an overall root-mean-square (rms) error of 0.25 mhartree (i.e., 0.16 kcal/mol) and a maximum absolute deviation of 1.93 mhartree (1.21 kcal/mol); for "noncompact'' conformations (no interatomic distance smaller than 1.15 bohr), the rms error is 0.17 mhartree (0.11 kcal/mol) and the maximum absolute deviation is 1.10 mhartree (0.69 kcal/mol). The classical barrier height for H+H2→H2+H is estimated to be 15.20±0.15 mhartree (i.e., 9.54±0.09 kcal/mol).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 95 (1991), S. 4331-4342 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: The interaction potential energy surface (PES) of H4 is of great importance for quantum chemistry, as a test case for molecule–molecule interactions. It is also required for a detailed understanding of certain astrophysical processes, namely, collisional excitation and dissociation of H2 in molecular clouds, at densities too low to be accessible experimentally. Accurate ab initio energies were computed for 6046 conformations of H4, using a multiple reference (single and) double excitation configuration interaction (MRD-CI) program. Both systematic and "random'' errors were estimated to have an rms size of 0.6 mhartree, for a total rms error of about 0.9 mhartree (or 0.55 kcal/mol) in the final ab initio energy values. It proved possible to include in a self-consistent way ab initio energies calculated by Schwenke, bringing the number of H4 conformations to 6101. Ab initio energies were also computed for 404 conformations of H3; adding ab initio energies calculated by other authors yielded a total of 772 conformations of H3. (The H3 results, and an improved analytic PES for H3, are reported elsewhere.) Ab initio energies are tabulated in this paper only for a sample of H4 conformations; a full list of all 6101 conformations of H4 (and 772 conformations of H3 ) is available from Physics Auxiliary Publication Service (PAPS), or from the authors.The best existing analytic PESs for H4 are shown to be accurate only for pairs of H2 molecules with intermolecular separations greater than about 3 bohr (1.6 A(ring)). High energy collisions (such as might lead to direct collisional dissociation) cannot be well represented by such surfaces. A more general analytic PES for H4 is required, which will be accurate for compact (high-energy) conformations and for conformations that cannot be subdivided into a pair of H2 molecules. Work in progress on devising such a surface (fitted to the 6101 conformations of this work) will be reported in a forthcoming paper.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1524-4741
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: From 1977 to 1986, 264 women with stage I or II breast cancer and positive breast cancer family histories were treated with conservative surgery, axillary dissection, and irradiation. The records of these cases were reviewed and compared to those of 517 women with stage I or II breast cancer and negative breast cancer family histories who were treated similarly during the same time period. Patients with a negative family history were more likely to present with positive axillary lymph nodes than patients whose history was positive (33% vs. 26.5%, p = 0.054). There were no statistically significant differences found between the family history positive and family history negative women in terms of 5 and 10 year actuarial overall survival (5 yr: 91% vs. 90%, 10 yr: 86% vs. 82%) or relapse-free survival (5 yr: 76% vs. 76%, 10 yr: 64% vs. 61 %). Breast recurrence rates were likewise not significantly different for the two groups of patients (5 yr: 6% vs. 9%, 10 yr: 17% vs. 18%). A separate analysis restricted to lymph node-positive patients revealed no significant differences in survival between the family history positive and family history negative groups. It thus appears that women with early stage breast cancer who have a family history of the disease can be treated with breast-conserving surgery and definitive irradiation with the same excellent results as seen in women without such a family history.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of veterinary emergency and critical care 12 (2002), S. 0 
    ISSN: 1476-4431
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of noninvasive electrocardiology 7 (2002), S. 0 
    ISSN: 1542-474X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Telemetry is done in a variety of settings with different levels of sophistication. The American College of Cardiology has made suggestions for telemetry monitoring but these are not in place in many smaller community hospitals that do telemetry monitoring. The objective of this study was to compare prospectively telemetry without a dedicated monitor watcher or full disclosure to results obtained on full disclosure. Patients included were admitted to a single community hospital with an indication for telemetry as judged by their primary physician. Telemetry results reported by the hospital staff were compared to over-read of full disclosure traces by an academic cardiology service and the patient was used as his own control. Significant rhythm disturbances including pauses of 2 seconds or greater and short runs of ventricular and supraventricular tachycardia were frequently missed when a dedicated monitor watcher and full disclosure were not in use. When a dedicated monitor watcher and full disclosure are not in use, telemetry results should be accepted with caution and attempts should be made to improve monitoring. A.N.E. 2002;7(3):219–221 telemetry; full disclosure; dedicated monitor watcher
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...