Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 377-383 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A photospectrometer has been realized in a standard integrated circuit (IC) process. Only the masks, materials, and fabrication steps inherent to this IC process were used (i.e., no post processing to add mechanical or optical devices for filtering). The spectrometer was composed of a set of 18 photodetectors with independent spectral responses. The responses of these devices were weighted and summed to form outputs proportional to the input optical power in discrete wavelength bands in the region from ∼400 to ∼1100 nm. With the solution space restricted to a 60 nm band, this instrument could resolve Gaussian input spectra (σ=5 nm) with a peak-to-peak spacing of less than 15 nm. This device could easily be integrated with additional analog, digital, or wireless circuits to realize a true laboratory instrument on-a-chip. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A battery-operated portable synchronous luminescence spectrofluorometer was developed for on-site analysis of groundwater or hazardous waste sites. The instrument is capable of either emission, excitation, or synchronous fluorescence measurements. The instrument is suited for trace analysis of important pollutants such as polyaromatic hydrocarbons, creosotes, and polychlorinated biphenyls in complex mixtures. The ability to perform synchronous luminescence measurements on these samples can reduce the complexity of fluorescence spectra and help in rapid field site characterization. A description of the instrumental components is given and an evaluation of the instrument using anthracene and several oil samples is provided to illustrate the usefulness of the instrument.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 1684-1687 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The TGV32, a 32-channel preamplifier–multiplicity discriminator chip for the multiplicity vertex detector (MVD) at PHENIX, is a unique silicon preamplifier in that it provides both an analog output for storage in an analog memory and a weighted summed-current output for conversion to a channel multiplicity count. The architecture and test results of the chip are presented. Details about the design of the preamplifier, discriminator, and programmable digital–analog converters performance as well as the process variations are presented. The chip is fabricated in a 1.2 μm, n-well, complementary metal–oxide–semiconductor process. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Clinical and experimental dermatology 27 (2002), S. 0 
    ISSN: 1365-2230
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary Pain resulting from photodynamic therapy (PDT) of skin cancer was investigated. The study included 69 lesions (60 patients) with different types of skin tumours or precursors. Protoporphyrin IX, which is produced by the topical application of δ-aminolevulinic acid, was used as a photosensitizing agent. Twenty-three of the lesions (19 patients) were examined with a fluorescence imaging system which demarcates the tumour area from the healthy skin and visualizes the contrast between the fluorescence from healthy skin and that from the tumour. EMLA® is used on all patients as part of our routine PDT protocol but despite this the major side-effect of PDT is pain during treatment. There is a large variation in pain intensity experienced by the patients, as measured by a visual analogue scale (VAS). Patients with actinic keratoses experienced more pain than those with Bowen's disease or basal cell carcinoma. The mean VAS score was higher when treating lesions located on the head than when treating lesions on the torso or the extremities. Also, treatment of large skin areas resulted in more pain than treatment of small areas, and men experienced more pain than women. The pain experienced by the patients did not correlate with treatment dose, Fitzpatrick skin type, age or fluorescence intensity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Environmental science & technology 8 (1974), S. 962-962 
    ISSN: 1520-5851
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of medicine & science in sports 7 (1997), S. 0 
    ISSN: 1600-0838
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Sports Science
    Notes: Forty-eight hour Holter monitoring was undertaken of 16 male elite middle- and long-distance runners, age 25±3 years, with peak oxygen uptake 4.83±0.43 1 O2/min or 73.0±3.9 ml O2/kg/min. The athletes had pronounced bradycardia during the night-time, with heart rate calculated from four RR intervals 〈30 beats/min in five runners. Twelve of 16 runners had RR intervals 〉2 s. Of those, 10 runners had sinus pauses exceeding 2 s, the longest being 3.06 s. Three runners had AV block II, two with Mobitz type 1, and one with both Mobitz type 1 and 2. Autonomic function was estimated by time domain and power spectral analysis of heart rate variability. The runners were compared with a control group of 13 sedentary or moderately active subjects. The runners had a mean of 14 b.p.m. lower heart rate at night than the controls. The runners had higher heart rate variability in all spectral bands. In the time domain pNN50 and rMSSD, which are considered to reflect strongly vagal tone, were markedly higher in the runners than the controls. The findings suggest that an increased parasympathetic tone might at least partly explain the pronounced resting sinus bradycardias found in endurance-trained runners.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of medicine & science in sports 6 (1996), S. 0 
    ISSN: 1600-0838
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Sports Science
    Notes: The aim of this study was to make descriptive analyses of the muscle activities in the lower extremity during maximal sprinting. Nine healthy sprinters were examined during maximal sprinting using telemetric electromyography (EMG). Seven muscles of the lower extremities were investigated: biceps femoris, medial hamstrings (semimembranosus and semitendinosus), rectus femoris, gluteus maximus, tibialis anterior, lateral gastrocnemius and medial gastrocnemius. The recorded EMG levels during running were expressed as percentage of maximum voluntary isometric contractions (%max EMG). For each muscle, the normalized EMG was plotted during the whole running stride cycle and is presented for each muscle. The reason for using this method is to show that it is possible to compare different muscle activities in a runner as well as to make comparisons between runners. Lateral and medial hamstrings and gluteus maximus showed similar activities with peak levels of EMG during footstrike. Rectus femoris had a two-peak activity, with one peak at the middle of the stance phase and the other during the swing phase. The tibialis anterior also showed a two-peak activity, but with the peaks at the beginning of the swing phase and just before foot-strike. The highest activities of the medial and lateral gastrocnemius occurred just before toe-off.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Physics and Chemistry of Solids 13 (1960), S. 235-243 
    ISSN: 0022-3697
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Annals of Physics 36 (1966), S. 323-362 
    ISSN: 0003-4916
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Annals of Physics 154 (1984), S. 356-395 
    ISSN: 0003-4916
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...