Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Title: ¬The¬ finite element method in heat transfer analysis
    Author: Lewis, R. W.
    Contributer: Morgan, K. , Thomas, H. R. , Seetharamu, K. N.
    Publisher: Chichester u.a. :Wiley,
    Year of publication: 1996
    Pages: 279 S.
    Type of Medium: Book
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Die zweidimensionalen instationären Navier-Stokes-und Energiegleichungen werden mittels der Finitelement-Methode für den Fall von 5 fluchtend übereinander liegenden Kreiszylindern gelöst. Die numerischen Lösungen der Grundgleichungen erfolgten über den expliziten Euler-Algorithmus, und zwar für eine Reynolds-Zahl von 100, eine Prandtl-Zahl von 0.71 und Richardson-Zahlen (Ri=Gr/Re 2) vonRi=−1.0; −0.5; 0.0; +0.5 und +1.0, jeweils für die beiden Verhältnisse Abstand/Durchmesser von 1.5 und 2.0. Stromlinien, Kurven gleicher Zirkulation, Druck- und Temperaturkonturen, lokale und mittlere Nusselt-Zahlen, Druck-und Scherspannungsverteilungen um die Zylinder werden dargestellt. Die für Zwangskonvektion (Ri=0) erhaltenen Ergebnisse stimmen gut mit zugänglichen experimentellen und numerischen Befunden überein. Auftriebseffekte sind sowohl bei förderlicher wie hemmender Anströmung von Bedeutung.
    Notes: Abstract Two dimensional unsteady Navier-Stokes and the energy equations are solved using finite element method for the case of flow past five row deep in-line bundle of circular cylinders with pitch to diameter ratios (PDR) of 1.5 and 2.0. Numerical solutions of governing equations have been obtained using Euler's explicit algorithm. Analysis have been made for Reynolds number of 100 and Prandtl number of 0.71. The effect of Richardson number (Ri=Gr/Re 2) on the flow and heat transfer have been investigated forRi=−1.0, −0.5, 0.0, +0.5 and +1.0. Streamlines, isovorticity lines, pressure and temperature contours, local and average Nusselt numbers, pressure and shear stress distribution around the cylinders are presented. Results obtained for forced convection (Ri=0.0) agree well with the available experimental and numerical results. There is considerable effect of buoyancy over tube bundles both in buoyancy aiding and opposing flows.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract An analysis of a crossflow plate-fin compact heat exchanger, accounting for the combined effect of two-dimensional longitudinal heat conduction through the exchanger wall and nonuniform inlet fluid flow distribution on both hot and cold fluid sides is carried out using a finite element method. Using the fluid flow maldistribution models, the exchanger effectiveness and its deterioration due to the combined effects of longitudinal heat conduction and flow nonuniformity are calculated for various design and operating conditions of the exchanger. It was found that the performance deteriorations are quite significant in some typical applications due to the combined effects of wall longitudinal heat conduction and inlet fluid flow nonuniformity on crossflow plate-fin heat exchanger.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Heat and mass transfer 32 (1996), S. 81-88 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung  Die durch Konvektionstrocknung bewirkte Temperatur- und Feuchteänderung in porösen Materialien wurde in einer eindimensionalen Analyse mittels der Methode der finiten Elemente untersucht. Unter Zugrundelegung konstanter Stoffwerte ermittelte Berechnungsergebnisse für Ziegel und Mörtel stimmen mit experimentellen Befund überein. Die Desorptionsdaten für beide Materialien wurden über die modifizierte Henderson-Gleichung ermittelt.
    Notes: Abstract  A one-dimensional finite element analysis has been carried out to study temperature and moisture variation of porous materials during convective drying. The predicted results for brick and mortar with constant transport properties agree with available experimental data. Henderson’s modified equation has been used to obtain the desorption data for the materials.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Heat and mass transfer 32 (1997), S. 427-433 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Mit Hilfe der Finitelement-Methode wurde die Doppeldiffusion bei natürlicher Konvektion in einem fluidgetränktem porösen Medium untersucht, wobei ein verallgemeinertes Modell für poröse Medien Verwendung fand, das sich sowohl für Darcysches, wie für nicht-Darcysches Fluidverhalten in einem achsialsymmetrischen Ringraum eignet. Aus den Ergebnissen geht hervor, daß die Darcy-Zahl als zusätzlicher Parameter eingeführt werden muß, um das Strömungsverhalten im nicht-Darcyschen Regime verstehen zu können. Die Porosität hat großen Einfluß auf den Wärme- und Stoffaustausch, so daß bei höheren Darcy- und Rayleigh-Zahlen diesbezüglich Unterschiede bis über 25% auftreten können. Im Vergleich mit den speziellen Modellen nach Darcy, Brinkman und Forchheimer liefert das hier untersuchte verallgemeinerte Modell die geringsten Wärme- und Stoffflüsse. Es zeigt sich ferner, daß die Vergrößerung des Radienverhältnisses höhere Nusselt- und Sherwood- Zahlen entlang der Innenwand zur Folge hat.
    Notes: Abstract Double-diffusive natural convection in a fluid saturated porous medium has been investigated using the finite element method. A generalised porous medium model is used to study both Darcy and non-Darcy flow regimes in an axisymmetric cavity. Results indicate that the Darcy number should be a separate parameter to understand flow characteristics in non-Darcy regime. The influence of porosity on heat and mass transfer is significant and the transport rates may differ by 25% or more, at higher Darcy and Rayleigh numbers. When compared with the Darcy and other specialised models of Brinkman and Forchheimer, the present generalised model predicts the least heat and mass transfer rates. It is also observed that an increase in radius ratio leads to higher Nusselt and Sherwood numbers along the inner wall.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Es werden numerische Lösungen für die Nusselt-Zahl während der Verdunstung eines bewegten Tropfens, der in direktem Kontakt mit der umgebenden ruhenden Säule aus unmischbarer Flüssigkeit steht, mitgeteilt. In der Berechnung wird der Einfluß der Blasenwachstumsrate auf die radiale Komponente der Tropfengeschwindigkeit berücksichtigt. Es wird festgestellt, daß die Nusselt-Zahl eine Funktion der Peclet-Zahl, der Jakobs-Zahl und des „Öffnungswinkels des Dampfes“ ist. Ein Vergleich der theoretischen und experimentellen Beziehungen für die Nusselt-Zahl zeigt gute Übereinstimmung. Die Berechnung enthält auch Informationen über das Temperaturprofil und die Dicke der thermischen Grenzschicht um den verdampfenden Tropfen.
    Notes: Abstract Numerical solutions for the Nusselt number during the direct contact evaporation of a moving drop in a stagnant column of immiscible liquid are presented. The effect of bubble growth rate on the radial component of drop velocity is taken into account in the analysis and the Nusselt number is found to be a function of Peclet number, Jakob number and vapour open angle. A comparison of theoretical and experimental correlations for the Nusselt number shows good agreement. The analysis also yields information on the temperature profile and the thickness of the thermal boundary layer surrounding the evaporating drop.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Heat and mass transfer 22 (1988), S. 219-222 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Es wurden Messungen durchgeführt, um den Einfluß verschiedener Konfigurationen von Füllkörpern auf das Verhalten eines Wirbelschicht-Kühlturms zu untersuchen. Die Experimente zeigten, daß die Form der Füllkörper einen ganz definierten Einfluß auf das Verhalten des Kühlturms hat und daß kugelförmige Füllkörper nicht die besten sind. Modifikationen von theoretischen Analysen, basierend auf dem einstufigen Gleichgewichtsmodell, helfen anhand der vorliegenden experimentellen Ergebnisse bei der Vorhersage des Verhaltens solcher Kühltürme, wenn verschiedene Füllkörperformen verwendet werden.
    Notes: Abstract Experimental investigations have been carried out to find out the effect of various configurations of the packing material on the performance of a Fluidized Bed Cooling Tower (FBCT). From the experiments it is observed that the shape of the packing material does have a definite effect on the performance of FBCT and the spherical shape is not the best shape. Modifications of the theoretical predictions based on the single stage equilibrium model in the light of the present experiments help in the predictions of the performance of the FBCT when various shapes of the packing material are used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Heat and mass transfer 26 (1991), S. 17-21 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Das Prinzip der Fluidisierung wird für Kühltürme eingesetzt. Die Leistung eines Wirbelschicht-Kühlturms mit geringer Größe ist als ermutigend angesehen worden. Deshalb wurde ein größerer Wirbelschicht-Kühlturm entwickelt, dessen Leistung ebenso gut eingestuft wurde. Der Druckverlust, der in einem Wirbelschicht-Kühlturm auftritt, ist mit dem Druckverlust in einem konventionellen Kühlturm vergleichbar. Die Packungshöhe in einem Wirbelschicht-Kühlturm verringert sich aufgrund der Fluidisierung wesentlich. In einer Tabelle wird gezeigt, daß die Durchflußleistung eines Wirbelschicht-Kühlturms erheblich größer ist, als bei konventionellen Kühltürmen.
    Notes: Abstract Application of the principles of the fluidization is made for cooling towers. The performance on a smaller size Fluidized Bed Cooling Tower (FBCT) is found to be encouraging. Hence a larger size FBCT is designed and the performance is found to be equally good. The pressure drop encountered in FBCT is comparable to that of conventional cooling towers. The packing height in FBCT reduces considerably because of fluidization. A table is provided to show that the throughput of the FBCT is greater than that of conventional cooling towers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Heat and mass transfer 24 (1989), S. 155-160 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Unter Anwendung der Differential-Interferometrie-Technik wurde eine experimentelle Arbeit auf dem Gebiet horizontaler Anordnungen von Kühlrippen durchgeführt. Die lokale Veränderung von Wärmestrom und Temperatur der mittleren Rippe einer Dreieranordnung wurde an transienten Heiz- und Kühlbereichen untersucht. Im transienten Zustand wurden die Durchschnittswerte der Wärmeübertragungskoeffizienten bei konstanter Wärmezuführ in das System für Aluminium und Flußstahl bei Zwischenräumen von 10 mm, 15 mm und 20 mm berechnet. Die Berechnungen wurden mit experimentellen Ergebnissen einer einzigen, auf einer Basis befestigten Rippe und einer vertikalen isothermen flachen Platte verglichen. Es wurde der Versuch gemacht, den Unterschied zwischen diesen Fällen, in bezug auf den physikalischen Mechanismus der Wärmeübertragung und Strömung über eine Rippenanordnung, zu erklären.
    Notes: Abstract Experimental work has been carried out on horizontal fin arrays using the differential interferometric technique. The local variations of heat flux and temperature in the central fin of a three fin array have been studied in the transient heating and cooling regimes. The average values of heat transfer coefficients in the transient state have been calculated for three spacings of 10 mm, 15 mm and 25 mm and with two materials namely aluminum and mild steel under constant heat input to the system. The results have been compared with experimental findings in the cases of a single fin attached to a base and a vertical isothermal flat plate. Attempt has been made to explain the differences between these cases in relation to the physical mechanism of heat and fluid flow about a fin array.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Heat and mass transfer 25 (1990), S. 9-15 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Es wurde eine Untersuchung der Grenzschicht bei freier Konvektion in einem gesättigten porösen Medium, das an eine nicht isotherme undurchlässige Oberfläche angrenzt, durchgeführt. Die Temperatur der undurchlässigen Oberfläche wurde als beliebige Ortsfunktion der Oberfläche angenommen. Lösungen werden in Form von Störungen des isothermen Falles erhalten. Unter Benutzung der Differentiale der Wandtemperatur, welche Ortsfunktionen der Oberfläche sind, werden als Störfunktion universelle Funktionen erhalten. Diese universellen Funktionen können benutzt werden, um die Wärmeübertragung für beliebige Variationen der Wandtemperatur zu bestimmen. Für einige spezielle Wandtemperaturen werden Lösungen unter Benutzung dieser universellen Funktionen abgeleitet und mit Lösungen aus der Literatur verglichen; gute Übereinstimmung kann festgestellt werden. Der Fall der einheitlichen Wandwärmestromdichte stellt sich als Spezialfall der nicht isothermen Lösung heraus.
    Notes: Abstract Boundary layer analysis is performed for free convection in a saturated porous medium adjacent to non-isothermal vertical impermeable surfaces. The impermeable surface temperature is assumed to be an arbitrary function of the distance along the surface. The solutions are obtained in the form of perturbations to the isothermal case. Using the differentials of the wall temperature, which are functions of distance along the surface, as perturbation elements, universal functions are derived. These universal functions can be used to estimate the heat transfer to any type of wall temperature variation. Solutions for some specialized wall temperature variations are derived using these universal functions and are compared with the solutions that are available in the literature. The agreement is found to be good. The case of uniform wall heat flux turns out to be a special case of non-isothermal wall solution.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...