Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Pediatric radiology 22 (1992), S. 287-289 
    ISSN: 1432-1998
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Over a two-and-one-half year period, 50 children underwent placements of jejunal tubes through a nasal route (NJ,n=47) or through an existing gastrostomy site (GJ,n=119). There were four attempted placements (98% success rate). The NJ tubes remained in place an average of 13 days, and the GJ tubes remained in place an average of 37 days. Fluoroscopic time for placement of an NJ tube averaged 6 min (29 cases), and for a GJ tube 8 minutes (91 cases). In spite of the limited retention time, fluoroscopic time, and availability of alternative methods, fluoroscopically placed jejunal feeding tubes are still playing an active role in this institution.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 38 (2000), S. 42-48 
    ISSN: 1741-0444
    Schlagwort(e): Bowel sounds ; Rat ; Motility ; Body acoustics ; Signal detection ; Signal characterisation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract This study is aimed at detecting gastrointestinal sounds (GIS) and correlating their characteristics with gastrointestinal (GI) conditions. The central hypotheses are that GIS generation depends on the motility patterns and the mechanical properties of the gut, and that changes in those result in measurable differences in GIS. An animal model which included both healthy rats and those with small bowel obstruction (SBO) was developed. The acoustic bursts, of GIS were detected by amplitude thresholding the signal envelope. Three methods of envelope estimation were proposed and evaluated. Envelope estimation using a Hilbert transform was found to produce the best results in the current application. The duration and dominant frequency of each detected GIS event was estimated and clear differences between healthy and diseased rats were discovered. In the control state, GIS events were found to consistently be of relatively short duration (3–65ms). Although the majority of events in the SBO state had similar short duration, infrequent longer events were also detected and appeared to be pathognomonic. Long duration events (〉100 ms) occurred in each of seven obstructed, but in none of 14 non-obstructed, cases (p〈0.001). It is concluded that GIS analysis may prove useful in the non-invasive, rapid, and accurate diagnosis of SBO.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...