Library

You have 0 saved results.
Mark results and click the "Add To Watchlist" link in order to add them to this list.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1520-5851
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Coupled GPC-GC ; gel permeation chromatography ; on-column interface ; co-solvent trapping ; gas chromatography ; large volume injection ; organophosphorus pesticides ; olive oil ; automation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The robustness of an automated on-line GPC-GC-FPD method for the determination of Organophosphorus (OP) Pesticides in olive oil has been significantly improved, now allowing a routine operation. The original GPC-GC transfer technique employed a loop type interface with an early vapor exit and co-solvent trapping. Shooting, caused by boiling delay and malfunctioning of the solvent vapor exit during the transfer of the 3 mL solvent fraction to the retention gap, resulted in insufficient focusing of the OP-pesticides. In this interfacing concept, the GPC fraction is introduced directly into the carrier gas stream during a certain time interval using the Dualchrom pressure- and flow regulation, resulting in a very stable transfer. The interface now basically corresponds to an on-column interface with flow regulation. Via a Pyrex glass door behind the GC-oven door it can be seen that the liquid flow is broken up into alternating gas-liquid segments by the carrier gas flow during transfer. This avoids shooting in the retention gap and broadens the temperature range for successful transfer. By using a smaller sized GPC column the solvent fraction transferred was reduced to 1.3 mL. Methyl acetate/cyclopentane and the co-solvent n-nonane were selected for their lower boiling points. The modified method is very robust and has been applied to the analysis of 28 different OP-pesticides in olive oil with an overall detection limit of 0.002 mg/kg. Routinely 24 h of unattended operation is possible with a cycle time of 75 min.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...