Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1520-5851
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Coupled GPC-GC ; gel permeation chromatography ; on-column interface ; co-solvent trapping ; gas chromatography ; large volume injection ; organophosphorus pesticides ; olive oil ; automation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The robustness of an automated on-line GPC-GC-FPD method for the determination of Organophosphorus (OP) Pesticides in olive oil has been significantly improved, now allowing a routine operation. The original GPC-GC transfer technique employed a loop type interface with an early vapor exit and co-solvent trapping. Shooting, caused by boiling delay and malfunctioning of the solvent vapor exit during the transfer of the 3 mL solvent fraction to the retention gap, resulted in insufficient focusing of the OP-pesticides. In this interfacing concept, the GPC fraction is introduced directly into the carrier gas stream during a certain time interval using the Dualchrom pressure- and flow regulation, resulting in a very stable transfer. The interface now basically corresponds to an on-column interface with flow regulation. Via a Pyrex glass door behind the GC-oven door it can be seen that the liquid flow is broken up into alternating gas-liquid segments by the carrier gas flow during transfer. This avoids shooting in the retention gap and broadens the temperature range for successful transfer. By using a smaller sized GPC column the solvent fraction transferred was reduced to 1.3 mL. Methyl acetate/cyclopentane and the co-solvent n-nonane were selected for their lower boiling points. The modified method is very robust and has been applied to the analysis of 28 different OP-pesticides in olive oil with an overall detection limit of 0.002 mg/kg. Routinely 24 h of unattended operation is possible with a cycle time of 75 min.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...