Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Aneurysm ; Transcranial colour-coded duplex sonography ; Embolisation ; Subarachnoid haemorrhage
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We examined 72 patients with 89 angiographically confirmed intracranial aneurysms, using transcranial colour-coded duplex sonography (TCCD) to determine the location and size of the aneurysm. The patients were admitted for coil embolisation of their aneurysm following subarachnoid haemorrhage or because of a cranial nerve palsy. Using a 2/2.25 MHz transducer, 42 aneurysms (47%) were seen satisfactorily through the temporal bone window or foramen magnum. In 24 cases (27%) image quality was insufficient as a result of a poor bone window, of the aneurysm having a diameter of less than 6 mm or of its being in an unfavourable location. In 23 other cases (26%) it was not possible to detect the aneurysm. Thrombosed structures could be demonstrated using TCCD in 8 of 12 giant intracavernous or basilar artery aneurysms, and in 15 of 19 aneurysms treated by platinum coil embolisation. TCCD offers a noninvasive method for monitoring progressive intra-aneurysmal thrombosis following coil embolisation and for follow-up of patients with untreatable fusiform aeurysms, should this be required. Detection of small aneurysms is limited by spatial resolution and insonation angles.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Aneurysm ; Transcranial colour-coded duplex sonography ; Embolisation ; Subarachnoid haemorrhage
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We examined 72 patients with 89 angiographically confirmed intracranial aneurysms, using transcranial colour-coded duplex sonography (TCCD) to determine the location and size of the aneurysm. The patients were admitted for coil embolisation of their aneurysm following subarachnoid haemorrhage or because of a cranial nerve palsy. Using a 2/2.25 MHz transducer, 42 aneurysms (47 %) were seen satisfactorily through the temporal bone window or foramen magnum. In 24 cases (27 %) image quality was insufficient as a result of a poor bone window, of the aneurysm having a diameter of less than 6 mm or of its being in an unfavourable location. In 23 other cases (26 %) it was not possible to detect the aneurysm. Thrombosed structures could be demonstrated using TCCD in 8 of 12 giant intracavernous or basilar artery aneurysms, and in 15 of 19 aneurysms treated by platinum coil embolisation. TCCD offers a noninvasive method for monitoring progressive intra-aneurysmal thrombosis following coil embolisation and for follow-up of patients with untreatable fusiform aneurysms, should this be required. Detection of small aneurysms is limited by spatial resolution and insonation angles.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗