Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 4314-4320 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: An instrument is described which combines a glancing incidence ion beam erosion system with a scanning tunneling and an atomic force microscope. This instrument allows the ion beam polishing and surface topographic characterization of conducting and insulating, crystalline, polycrystalline, and amorphous samples under ultrahigh vacuum conditions. As an illustration of the capability of the instrument and the polishing technique, we present results demonstrating a fivefold improvement in rms roughness of a polycrystalline Cr film and a fivefold reduction in rms roughness of a vicinal, initially mechanically polished CaF2 (111) sample. The final rms roughness of the latter sample of 0.12±0.04 nm measured over the bandwidth of 10–500 nm is just 75% of the Ca–F interlayer spacing for the (111) surface orientation. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-0509
    Schlagwort(e): Key words: MRI—Hepatic imaging—RARE—Detection—Characterization.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. Background: We compared two T2-weighted turbo spin echo (TSE) sequences with a T2-weighted conventional SE (CSE) sequence to determine whether sequences derived from rapid acquisition with relaxation enhancement such as TSE could replace CSE for the detection and subsequent characterization of focal liver lesions. Methods: A total of 55 consecutive patients with 107 liver lesions underwent magnetic resonance imaging examinations at 1.5 Tesla, with a constant imaging protocol. TSE pulse sequences were acquired with eight echo trains (repetition time [TR], 4718 ms; echo time [TE], 90 ms; acquisition time [TA], 4.03 min; and a symmetric k-space ordering scheme) and 11 echo trains (TR, 4200 ms; TE, 140 ms; TA, 4.40 min; and an asymmetric k-space ordering scheme) and compared with CSE (TR, 2300 ms; TE, 45/90 ms; TA, 9.53 min). Images were analyzed qualitatively by scoring image quality and artifacts and counting focal liver lesions by independent reading with consensus obtained for discrepancies. Quantitative analysis was performed by measuring signal-to-noise (S/N), contrast-to-noise (C/N), and tumor–liver signal intensity (T/L) ratios. Results: T2-weighted TSE sequences provided better subjective image quality and reduced artifacts as compared with the T2-weighted CSE sequence. CSE and TSE sequences exhibited no statistically significant differences in liver S/N, lesion–liver C/N (CSE TE, 90 ms: 18.6 ± 14.0; TSE TE, 90 ms: 16.5 ± 12.9) and the detectability of focal liver lesions. Heavily T2-weighted TSE with a TE of 140 ms allowed correct characterization of focal liver lesions based on a T/L ratio of 3.0 in 84% of patients. Conclusions: T2-weighted TSE sequences are as suited as CSE for the detection (TE, 90 ms), and appear to be superior for the characterization (TE, 140 ms), of focal hepatic lesions. Whether a single sequence, such as a double-echo TSE or a single-echo TSE sequence with a TE between 110 and 120 ms, might perform both functions as well or better than CSE is unknown. However, because of time savings, TSE eventually may be preferred over CSE.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...