ISSN:
0001-1541
Keywords:
Chemistry
;
Chemical Engineering
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
,
Process Engineering, Biotechnology, Nutrition Technology
Notes:
A parallel-plate thermal diffusion column packed with glass wool was operated in continuous flow. The standard equation used for continuous flow through nonpacked columns satisfactorily correlates separation and flow rate. The packed-column theory correctly gives the effects on the regression coefficients of plate spacing and packing permeability, the two variables unique in the packed column. The theory gives poor approximations of the absolute magnitudes of the coefficients, however, which is the same situation found in results from nonpacked columns.
Additional Material:
4 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/aic.690130608