Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 13 (1967), S. 1077-1080 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A parallel-plate thermal diffusion column packed with glass wool was operated in continuous flow. The standard equation used for continuous flow through nonpacked columns satisfactorily correlates separation and flow rate. The packed-column theory correctly gives the effects on the regression coefficients of plate spacing and packing permeability, the two variables unique in the packed column. The theory gives poor approximations of the absolute magnitudes of the coefficients, however, which is the same situation found in results from nonpacked columns.
    Additional Material: 4 Ill.