Temperature control of subcooled reflux in a distillation column was studied experimentally using coolant flow rate as the manipulative variable. Methanol vapor was condensed and subcooled at one atmosphere in a vertical heat exchanger with 210 copper tubes (0.77 cm I.D., 91.5 cm long). Cooling water flowed countercurrently through the shell side (20.6 cm I.D.).A proportional-integral feedback controller provided good temperature control at normal design throughputs. But dynamic control performance deteriorated at low throughputs (or large areas). Thus the normal conservative design practice of providing excess area in this type of condenser leads to poorer temperature control.