ISSN:
0001-1541
Schlagwort(e):
Chemistry
;
Chemical Engineering
Quelle:
Wiley InterScience Backfile Collection 1832-2000
Thema:
Chemie und Pharmazie
,
Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
Notizen:
A design approach based on a phase diagram of inlet temperatures is proposed for the countercurrent reactor/heat exchanger for highly exothermic reactions with inherent parametric sensitivities. The phase diagram shows the region of safe operation on a plane of feed and coolant inlet temperatures, free from runaway conditions. The boundaries surrounding the safe operation region are defined by design parameters. Simple procedures applicable to arbitrary expressions of global rate are developed for the phase diagram. The multi-pronged design problem of selecting the design parameters and operating conditions for the maximum possible conversion within the constraints due to the parametric sensitivities is condensed into the represented by a phase diagram and an analysis on the phase plane. A design alternative which eliminates the necessity of the preheater for highly exothermic reactions is discussed and the advantages are quantitatively illustrated to assert that this design should be seriously considered as a viable alternative.
Zusätzliches Material:
7 Ill.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1002/aic.690290112