Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 1483-1500 
    ISSN: 0887-6266
    Keywords: dilute polystyrene solution ; flow birefringence ; transient elongational flow ; local orientation angle ; polymer molecular weight ; affine deformation model ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Transient elongational flow, created by forcing a polymer solution across a narrow contraction, is characterized by a high strain rate of limited duration. Due to an inherent short residence time, this type of flow generally is considered as being less efficient in extending isolated flexible molecular coils than “stagnation” point elongational flow. Rheo-optical measurements revealed, nevertheless, a readily detectable birefringence zone above a critical strain rate in the immediate orifice entrance. Birefringence was studied for dilute PS solutions (100-400 ppm) in decalin as a function of fluid strain rate (\documentclass{article}\pagestyle{empty}\begin{document}$\dot \varepsilon $\end{document} = 1000-38,000 s-1) and polymer molecular weight (M = 1.93-10.2·106). Transient elongational flow is complicated by the presence of local orientation distribution along the different streamlines. To account for this effect, a numerical technique has been devised to compute local birefringence (Δn) from experimental retardation (δ). Results show a uniform birefringence distribution across the capillary entrance and a steep decrease with the axial distance. Molecular extension ratio calculated with the Kuhn-Grün theory suggests that polymers may uncoil up to one third of the chain contour length at the approach of capillary entrance. Although extension ratio determined at the inlet could be fitted with an affine deformation model, notable departure from this simple representation is observed when molecular strain is calculated along the streamline. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 1483-1500, 1998
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...