Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 12 (1991), S. 105-117 
    ISSN: 1572-9567
    Keywords: capillary viscometer ; fluorocarbons ; refrigerants ; viscosity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Viscosity measurements were carried out on saturated liquid fluorocarbon refrigerants using an improved capillary viscometer for 11 kinds of fluorocarbon refrigerants; CCl3F (R11), CCl2F2 (R12), CHClF2 (R22), CBrF3 (R13B1), CH3CHF2 (R152a), CCl2FCClF2 (R113), CHCl2CF3 (R123), CHClFCClF2 (R123a), CH3CF3 (R143a), CClF2CCl2F2 (R114), and CH2FCF3 (R134a), in the temperature range from 273 to 353 K. An equation is given to represent the viscosity as a function of temperature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗