    Documenta ophthalmologica 75 (1990), S. 239-246 
    ISSN: 1573-2622
    Keywords: Diaphany ; translucency ; straylight ; glare ; light scatter ; X-linked megalocornea ; contrast sensitivity ; visual optics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Intraocular straylight can be measured, in clinical as well as normal cases, by the direct compensation technique. Intraocular straylight is known to originate from the cornea, lens and fundus. We have studied a fourth source: the translucency of the iris and surrounding ocular wall. For lightly-pigmented normal eyes this source proved to be important. In the present paper results are reported from a patient with X-linked megalocornea. He had diaphany of the iris, as is common in these patients, and photophobic complaints. Quantitative measurements showed that the translucency was much increased so that the intraocular straylight was far above the normal level.