Cesium volume reactions are included in a two-point model numerical code for a high power hydrogen negative ion source. The energy balance equation for the electron temperature and rate equations of Cs and Cs+ are included in our code to investigate the electron cooling and volume effects by cesium seeding. Cesium density in the ion source is taken as a variable for the calculation. Cesium is ionized over 95% in the driver region of the ion source. The electron temperature begins to decrease at cesium density 1011 cm−3 and the electron density increases because of the ionization of cesium. © 2000 American Institute of Physics.