Publication Date:
2014-02-26
Description:
The breakdown voltage highly depends on the electric field in the depletion area whose computation is the most time consuming part of the simulation. We present a self adaptive Finite Element Method which reduces dramatically the required computation time compared to usual Finite Difference Methods. A numerical example illustrates the efficiency and reliability of the algorithm.
Keywords:
ddc:000
Language:
English
Type:
reportzib
,
doc-type:preprint
Format:
application/pdf