Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    BIT 15 (1975), S. 85-93 
    ISSN: 1572-9125
    Keywords: internal sorting ; quicksort ; samplesort ; minimal-storage sorting ; tree-sort
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Notes: Abstract An implementation of samplesort, a generalization of minimal-storage tree-sorting, is presented as an algorithm which is relatively insensitive to possible non-random permutations of the elements to be sorted. A brief analytical discussion and the results of extensive empirical tests are included. It is claimed that with the particular choice of samplesize, samplesort is probably one of the most efficient, if not the most efficient sorting algorithm known.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Research in experimental medicine 188 (1988), S. 139-149 
    ISSN: 1433-8580
    Keywords: Intestinal transport ; 1,25 (OH)2D3 ; Calcium ; Phosphorus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The unidirectional ileal transport of calcium (Ca) and inorganic phosphorus (Pi) of rats was measured in vitro with the modified Ussing technique. Animal preparation included 5/6 nephrectomy and EHDP treatment. They were compared to controls as well as to 1,25 (OH)2D3 supplemented rats. The results show that the ileum is a secretory organ for Ca and Pi, the serosa to mucosa transport (Jsm) exceeds the mucosa to serosa transport (Jms). Ca and Pi transport in sm direction is 1,25 (OH)2D3 independent but exhibits a mutual strong correlation. Our observations together with published data are in favor of mainly paracellular, non electrogenic sm transport of both ions. However, the factor controlling sm transport of Ca and Pi remains unidentified. The mucosa to serosa transport (Jms) in the ileum is low for both ions. Ca ms is stimulated by 1,25 (OH)2D3, Pi ms is unchanged.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: ARDS ; Extracorporeal circulation ; Extracorporeal CO2-removal ; Extracorporeal membrane oxygenation ; Gas exchange
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Extracorporeal circulation can cause lung damage, which would be especially counterproductive during extracorporeal gas exchange for the treatment of acute respiratory failure. To test the hypothesis that partial venovenous bypass with extracorporeal CO2-removal combined with low-frequency positive pressure ventilation (ECCO2R-LFPPV) can adversely affect lung fluid balance, extravascular thermal lung volume (ETV) and hemodynamics were assessed before, during and after ECCO2R-LFPPV in normal closed ehest dogs. In series I dogs (n=6) subjected to 10 h of ECCO2R-LFPPV, ETV did not change significantly from control (7.1 ml/kg±0.99 SE) during or after bypass. Gravimetric extravascular lung water and lung histology after bypass were found to be normal. In series II dogs (n=5), subjected to shorter periods of ECCO2R-LFPPV, ETV also remained unchanged. In contrast to previous reports using sheep, pulmonary arterial hypertension during bypass was not observed. Thus, ECCO2R-LFPPV was not associated with increased lung water, pulmonary hypertension or morphological lung changes under the conditions studied and does not seem to cause lung damage in normal lungs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1238
    Keywords: Acute respiratory failure ; Anticoagulation ; Artificial lung ; Extracorporeal gas exchange
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Treatment of severe acute respiratory failure with extracorporeal gas exchange necessitating near complete systemic anticoagulation requires a delicate balance to be maintained between disseminated intravascular coagulation and hemorrhagic complications. The present study describes our first experience using a heparin coated extracorporeal artificial lung and circuitry during clinical extracorporeal CO2 removal. In spite of a partial thromboplastin time and activated clotting time within or close to the normal range, neither laboratory evidence for disseminated intravascular coagulation induced by the extracorporeal circuit nor thrombi in the pulmonary vasculature were found. Scanning electron microscopy of the heparin coated hollow fiber gas exchanger demonstrated only minor deposits on the surface. Use of a heparin coated artificial lung may enhance the margin of safety of extracorporeal gas exchange and ultimately broaden its indications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...