Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1975-1979  (2)
  • 1965-1969
  • 1977  (2)
Material
Years
  • 1975-1979  (2)
  • 1965-1969
Year
  • 1
    ISSN: 0942-0940
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A case of partially occluding post-traumatic thrombosis of the internal carotid artery and secondary embolism of the middle cerebral artery is reported. The patient was treated with Thrombolysin with coincident resolution of clinical symptoms and signs and clearing of the lesions on arteriography. This may have been fortuitous. The subject of traumatic carotid artery thrombosis is reviewed in detail, and its pathophysiology is discussed, especially in relation to facts known about occlusive vascular disease secondary to atherosclerosis and related embolie phenomena. Suggestions are made concerning the treatment of this condition, especially with regard to developing rational criteria for opening vascular beds through evaluation of collateral cerebral blood flow. The uses of microvascular surgical techniques and thrombolytic therapy are considered.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 297-314 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Collagen tubes were tanned with glutaraldehyde for different periods of time. Some were oxidized with periodate and sterilized with either 60Co (1.5 Mrad) or propylene oxide. The tubes were coated with polyfilamentous polyester fabric, filled with x-ray contrast material, and implanted subcutaneously in rats and rabbits. Rate of resorption was ascertained by x-ray procedure of progressive leakage of contrast material.A close relation between tanning time of the collagen fabric-combined prostheses and rate of their resorption in subcutis was found in both rats and rabbits. In rabbits, however, the implants were resorbed at a significantly faster rate than in rats. No effect of oxidation of collagen on the resorption was observed. Collagen tubes tanned for shorter time periods and sterilized with propylene oxide were more resistant to degradation than those sterilized with irradiation. This difference was absent, however, with material tanned for longer times.The mechanism of resorption of implanted collagen tubes was studied by morphological methods. The role of inflammatory cells in resorption is documented. The paper indicates the advantages as well as limits of the x-ray method of studying the resorption rate of biodegradable materials.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...