Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
  • 1960-1964
  • 1985  (3)
Material
Years
  • 1985-1989  (3)
  • 1960-1964
Year
  • 1
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The small-angle scattering facility at Daresbury has been constructed for diffraction studies of a wide range of naturally occurring and synthetic materials. The high brightness of the SRS is combined with focusing optics, resulting in exposure times that can be two or three orders of magnitude less than those required on a conventional source. Spacings of 2000 Å in the vertical direction and 300 Å in the horizontal direction can be observed, while the resolution between diffraction orders is 5000 and 600 Å. In addition, preliminary results have been obtained on a double-crystal diffractometer that has a resolution, in one dimension, of better than 26 000 Å. For high-angle fibre diffraction studies, a camera with pinhole collimation has been constructed. Examples from solution scattering and fibre diffraction are used to illustrate the performance of these facilities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 29 (1985), S. 395-399 
    ISSN: 1432-1041
    Keywords: Ro 31-1118 ; cardioselectivity ; hypertension ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Five patients with mild hypertension were given single oral doses of Ro 31-1118 (10, 20, 40, and 80 mg) and placebo in a randomized, double-blind, within-patient study. Plasma concentrations of Ro 31-1118 and supine, standing, exercise, and post-exercise heart rates and blood pressures were measured before and at regular intervals after drug administration. The pharmacokinetic data were consistent with a one-compartment model with first-order absorption and a variable time lag. Peak plasma concentrations and area under curve were linearly related to dose, whereas time to peak concentration, half-time, clearance and apparent volume of distribution were dose-independent. There was a reduction in exercise and post-exercise heart rate of approximately 10% after 10 mg and 20 mg Ro 31-1118, and of approximately 15% after 40 mg and 80 mg. At all doses standing systolic blood pressure was reduced by approximately 5%. A similar fall was seen in exercise and post-exercise systolic blood pressures. There was no substantial effect of Ro 31-1118 on supine or standing heart rates nor on diastolic blood pressure. No adverse effects were reported. It is concluded that Ro 31-1118 has linear pharmacokinetics over the dose range 10–80 mg, and has a weak antihypertensive effect when administered in single doses to patients with mild hypertension.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of fracture 28 (1985), S. 151-160 
    ISSN: 1573-2673
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Résumé On a calculé le déplacement d'ouverture au centre d'une fissure de surface dans une sphère soumise à pression interne, en utilisant un modèle de déformation plastique d'une bande. Pour déterminer le COD, on a procédé à une extension de la solution appliquéc à une coque mince pour obtenir le facteur d'intensité d'entaille selon Folias, et les équations obtenues ont été résolues par voie numérique, en suivant une procédure due à Erdogan. Les résultats peuvent être utilisés à la prédiction d'une rupture ainsi qu'au calcul de la vitesse de fuite d'un gaz contenu dans un récipient.
    Notes: Abstract The crack opening displacement at the centre of a surface crack in a pressurized sphere has been calculated using a strip yielding model. The shallow shell solution for the stress intensity factor derived by Folias has been extended to derive the COD, and the resulting equations have been solved numerically by a procedure due to Erdogan. The results are of relevance to fracture predictions and gas leakage rate calculations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...