Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (4)
  • 1995-1999
  • 1990-1994  (3)
  • 2000  (4)
  • 1990  (3)
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 93 (1990), S. 6859-6864 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: The unoccupied molecular orbitals of metal-free phthalocyanine (H2PC), nickel-phthalocyanine (NiPC), and copper-phthalocyanine (CuPC) adsorbed on single crystal surfaces have been studied by inverse photoemission spectroscopy (IPES) and near-edge x-ray absorption spectroscopy (NEXAFS). The features observed in the experimental data are assigned by reference to molecular orbital calculations. Carbon and nitrogen 1s NEXAFS measurements of NiPC adsorbed on Cu(110) surface indicates that the phthalocyanine molecular planes are parallel to the surface. X-ray absorption data recorded at the Ni LIII and LII edges show that the unoccupied Ni 3d level is located in the plane of the phthalocyanine rings.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Contact dermatitis 43 (2000), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The aim of the present paper is to evaluate whether increasing environmental exposure increases the frequency of the positive prick and patch test reactions to certain chlorinated platinum salts in patients with dermatitis and urticaria. 800 consecutive subjects with contact dermatitis (n=749) and urticaria (n=51) were variously patch and prick tested with 30 haptens of a standard series, with aqueous solutions of, respectively, hexachloroplatinic acid (H2[PtCl6]), potassium tetrachloroplatinate (K2[PtCl4]), sodium hexachloroplatinate (Na2[PtCl6]), iridium chloride (IrCl3), rhodium chloride (RhCl3) and palladium chloride (PdCl2), and with 16 common inhalants. 153 workers, variably exposed in a platinum refinery, were patch and prick tested only with solutions containing platinum-group elements at various concentrations and with 16 common inhalants. Platinum-group elements did not elicit positive patch or prick test reactions in non-occupationally exposed subjects. In contrast, in exposed workers, positive patch test reactions at day 2 and at 25 min, respectively, were found in 2 subjects with hand dermatitis and in 2 with urticaria and asthma. 22 out of the 153 workers, 18 of whom had rhinitis, asthma, and urticaria, gave positive prick test reactions to 1 or more salts. Furthermore, on patch and prick testing, 4 cross-reactions between platinum, palladium, iridium and rhodium were demonstrated. In conclusion, the test results demonstrate that the present concentration in the environment does not increase the incidence of reactions to platinum salts in patients with dermatitis and/or urticaria. However, if the average level of environmental platinum exposure approaches those existing in industrial settings in the future, we are going to observe more frequent health effects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: COPD ; High frequency jet ventilation ; Auto-PEEP
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We investigated the levels of auto-PEEP and dynamic hyperinflation during high frequency jet ventilation (HFJV) and controlled mechanical ventilation (CMV) in six patients with chronic obstructive pulmonary disease within the first 36 h of acute exacerbation. The comparative evaluation was performed at similar conditions of gas exchange in HFJV and CMV: PaO2 77.6±11 mmHg vs 80.8±12 mmHg; PaCO2 46.8±2.5 mmHg vs 47±2.8 mmHg; pH 7.38 vs 7.38. In this situation, the values of auto-PEEP and dynamic hyperinflation, expressed as Δ over the apneic functional residual capacity (FRC) did not differ: (auto-PEEPHFJV 8.9±3.8 cmH2O; auto-PEEPCMV 8.8±4.7 cmH2O; ΔFRCHFJV 0.56±0.19 l; ΔFRCCMV 0.54±0.2 l). This result suggests that, with a suitable machine setting and similar gas exchanges, HFJV produces the same level of auto-PEEP and dynamic hyperinflation as CMV in patients with chronic obstructive pulmonary disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1238
    Keywords: Heat-moisture exchangers ; COPD ; Auto PEEP ; Controlled mechanical ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In recent years the use of devices called Heat and Moisture Exchangers (HME) has become widespread as gas conditioners for ICU patients requiring mechanical ventilation. As an important variation of the resistive properties of the HME, related to flow and duration of use, has recently been pointed out during “in vitro” studies, the use of these devices in COPD patients could increase the levels of auto PEEP and dynamic hyperinflation. In this study we have compared the levels of auto PEEP and difference in functional residual capacity (Δ FRC) in a group of COPD patients, requiring controlled mechanical ventilation (CMV), at basal conditions and after the insertion into the circuit of three HMEs (Dar Hygrobac, Pall Ultipor, Engstrom Edith) at random: the results obtained excluded a significant increase of auto PEEP and Δ (FRC) both with “new” HMEs and after 12 h of continuous use.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 159 (2000), S. 579-581 
    ISSN: 1432-1076
    Keywords: Key words Osteopetrosis ; Rickets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report the case of a baby girl who presented with rickets at 3 months. At the age of 5 months she was readmitted because of nystagmus and a diagnosis of osteopetrosis was made on the basis of clinical and radiological findings. Rickets is a paradoxical feature of osteopetrosis resulting from inability to maintain a normal calcium-phosphorus balance. In our patient the onset of rickets before other symptoms of osteopetrosis suggests a primary defect. Conclusion It is possible that patients with osteopetrosis and rickets (osteopetrorickets) represent a different mutation like the osteopetrosis mouse, which is the only animal mutation with rickets.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-2277
    Keywords: Key words HLA class I matching ; Cadaveric renal transplant ; Crossreactive antigens (CREG) ; Flow cytometric crossmatch (FCXM) ; Anti-HLA alloantibodies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Donor-recipient HLA matching was retrospectively evaluated in 111 cadaveric renal transplants using Takemoto's ten-residue model in which HLA class I antigens are clustered by crossreactive group (CREGs) on the basis of amino acid sequence homology and the sharing of a particular public epitope. The grade and type of HLA residue mismatching were correlated to posttransplant, class I donor-specific antibody production (monitored by flow cytometry crossmatch), rejection occurrence and clinical outcome during the 1st year posttransplant. In 52 patients with 0 mismatchings (MMs) we observed a low incidence of rejection (11.1 %) and antibody production (11.1 %) for 0 CREG MM grade, while 1 MM was enough to increase immune response against graft (rejection 35 %; antibodies 30 %). Moreover, a significant correlation was observed between Q144, E163, Q62 and L82/R82 epitopes and the incidence of acute rejection and antibody production (“immunogenic” residues) in patients grouped for a single residue mismatch.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1573-2665
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...